Brandt Maryann, McCullor Kimberly, Harris Don, Ratzlaff Zachary, Thompson Eric, Pfeifer Cory M
Microbiology Laboratory, Phoenix Children's, Phoenix, Arizona.
Michigan Department of Health and Human Services, Bureau of Laboratories, Lansing, Michigan.
Proc (Bayl Univ Med Cent). 2023 Feb 8;36(3):354-359. doi: 10.1080/08998280.2023.2169556. eCollection 2023.
The aim of our study was to evaluate a protocol utilizing serum separator tubes (SST) to facilitate a faster, cost-effective, direct method for rapid sensitivity testing and identification of positive blood cultures. Spiked cultures were inoculated into either Becton Dickinson (BD) BACTEC Aerobic Plus or Anaerobic/F bottles containing sterile human blood. Bottles were immediately processed when positive. A parallel study using patient isolates was used in which bacteria were pelleted by SST from positive blood cultures. For identification, a portion of the pellet was tested by matrix-assisted laser desorption/ionization as described by the manufacturer. MicroScan panels and Vitek 2 results were compared. Categorical agreement was used as comparison to standard subculture and/or polymerase chain reaction methods. No discordant identifications were observed, and 86% generated a successful identification when compared to subculture methods. For the Vitek 2, we observed a 99% essential agreement when compared to the subculture method. For the MicroScan Walkaway, we observed 94.9%, 97.4%, and 100% categorical agreement for MIC panels 53, 38, and MICroSTREP Plus 2, respectively. Turnaround times were reduced from 4 hours for identification and 11 hours for antimicrobial sensitivity testing. We conclude that the SST method results in timelier, actionable results for antimicrobial stewardship initiatives.
我们研究的目的是评估一种使用血清分离管(SST)的方案,以促进一种更快、更具成本效益的直接方法,用于快速敏感性测试和阳性血培养物的鉴定。将加标的培养物接种到含有无菌人血的Becton Dickinson(BD)BACTEC需氧增强型或厌氧/瓶中。培养瓶阳性时立即进行处理。使用了一项平行研究,该研究使用患者分离株,其中通过SST从阳性血培养物中沉淀细菌。为了进行鉴定,按照制造商的说明,通过基质辅助激光解吸/电离对一部分沉淀进行测试。比较了MicroScan板和Vitek 2的结果。将分类一致性用作与标准亚培养和/或聚合酶链反应方法的比较。未观察到不一致的鉴定结果,与亚培养方法相比,86%的鉴定成功。对于Vitek 2,与亚培养方法相比,我们观察到99%的基本一致性。对于MicroScan Walkaway,我们分别观察到MIC板53、38和MICroSTREP Plus 2的分类一致性为94.9%、97.4%和100%。鉴定周转时间从4小时缩短至抗菌敏感性测试的11小时。我们得出结论,SST方法可为抗菌管理举措带来更及时、可采取行动的结果。