感兴趣区勾画对镓-PSMA PET/CT中肝脏信噪比测量稳定性和可重复性的影响

Impact of Region-of-Interest Delineation on Stability and Reproducibility of Liver SNR Measurements in Ga-PSMA PET/CT.

作者信息

Fooladi Masoomeh, Rezaei Sahar, Aghahosseini Farahnaz, Salehi Yalda, Kasraie Nima, Sheikhzadeh Peyman

机构信息

Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran.

Department of Radiology, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.

出版信息

World J Nucl Med. 2023 May 16;22(2):124-129. doi: 10.1055/s-0043-1768446. eCollection 2023 Jun.

Abstract

This study aims to assess the impact of various regions of interest (ROIs) and volumes of interest (VOIs) delineations on the reproducibility of liver signal-to-noise-ratio (SNRliver) measurements, as well as to find the most reproducible way to estimate it in gallium-68 positron emission tomography ( Ga-PET) imaging. We also investigated the SNRliver-weight relationship for these ROIs and VOIs delineations.  A cohort of 40 patients (40 males; mean weight: 76.5 kg [58-115 kg]) with prostate cancer were included. Ga-PET/CT imaging (mean injected activity: 91.4 MBq [51.2 MBq to 134.1 MBq] was performed on a 5-ring bismuth germanium oxide-based Discovery IQ PET/CT using ordered subset expectation maximization image reconstruction algorithm. Afterward, circular ROIs and spherical VOIs with two different diameters of 30 and 40 mm were drawn on the right lobe of the livers. The performance of the various defined regions was evaluated by the average standardized uptake value (SUV ), standard deviation (SD) of the SUV (SUV ), SNR , and SD of the SNR metrics.  There were no significant differences in SUV among the various ROIs and VOIs (  > 0.05). On the other hand, the lower SUV was obtained by spherical VOI with diameter of 30 mm. The largest SNR was obtained by ROI (30 mm). The SD of SNR with ROI (30 mm) was also the largest, while the lowest SD of SNR was observed for VOI (40 mm). There is a higher correlation coefficient between the patient-dependent parameter of weight and the image quality parameter of SNRliver for both VOI (30 mm) and VOI (40 mm) compared to the ROIs.  Our results indicate that SNR measurements are affected by the size and shape of the respective ROIs and VOIs. The spherical VOI with a 40 mm diameter leads to more stable and reproducible SNR measurement in the liver.

摘要

本研究旨在评估不同感兴趣区域(ROI)和感兴趣体积(VOI)的划定对肝脏信噪比(SNRliver)测量可重复性的影响,并找到在镓-68正电子发射断层扫描(Ga-PET)成像中估计SNRliver的最可重复方法。我们还研究了这些ROI和VOI划定的SNRliver-体重关系。纳入了40例前列腺癌患者队列(40例男性;平均体重:76.5 kg [58 - 115 kg])。使用有序子集期望最大化图像重建算法,在基于五环氧化铋锗的Discovery IQ PET/CT上进行Ga-PET/CT成像(平均注入活度:91.4 MBq [51.2 MBq至134.1 MBq])。之后,在肝脏右叶绘制直径为30和40 mm的两种不同直径的圆形ROI和球形VOI。通过平均标准化摄取值(SUV )、SUV的标准差(SD)(SUV )、SNR 以及SNR 的SD指标评估各种定义区域的性能。不同ROI和VOI之间的SUV 无显著差异(  > 0.05)。另一方面,直径为30 mm的球形VOI获得的SUV 较低。ROI(30 mm)获得的SNR 最大。ROI(30 mm)的SNR 的SD也是最大的,而VOI(40 mm)的SNR 的SD最低。与ROI相比,VOI(30 mm)和VOI(40 mm)的体重相关患者参数与SNRliver的图像质量参数之间的相关系数更高。我们的结果表明,SNR 测量受各自ROI和VOI的大小和形状影响。直径为40 mm的球形VOI可导致肝脏中SNR测量更稳定且可重复。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/42a1/10202577/cad009b08cd0/10-1055-s-0043-1768446-i22120006-1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验