Suppr超能文献

Alivecor KardiaMobile智能手机调制心电图设备在马匹中的应用。

Application of the Alivecor KardiaMobile smartphone modulated ECG device for use in horses.

作者信息

Piketh G, Williams A, Schliewert E C

机构信息

Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, South Africa.

Head of Equine and Data, Research and Ai Executive Manager, Vet-Ai Information, United Kingdom.

出版信息

J S Afr Vet Assoc. 2024 Mar;95(1):20-27. doi: 10.36303/JSAVA.540. Epub 2023 Jun 22.

Abstract

Electrocardiography is the method used to monitor the electrical impulses in the heart. These diagnostics are increasingly making use of smartphone-based technologies. The objective of this research was to determine whether the Alivecor KardiaMobile (ECG) smartphone-modulated electrocardiographic device, a novel ECG device, can be used to obtain reliable electrocardiogram (ECG) readings in horses. The device was initially tested in 36 Nooitgedacht pony mares to determine the best site of application, method of skin preparation, and ECG device orientation for reliable ECG tracings. Once the most reliable site for ECG acquisition was determined, the device was then applied, in this manner, to 31 Nooitgedacht pony mares and compared with a standard telemetric ECG system (ECG). The ECG device was best applied in the fourth intercostal space on the left hemithorax in a vertical orientation and with the skin dampened with 70% ethanol. Mean values determined for RR and QT intervals between the ECG and ECG were not significantly different, however, mean values for the duration of the QRS complexes were significantly different for the two devices. There is acceptable agreement between the ECG and ECG devices with regards to the measurement of the PQ; RR and QT intervals but not the QRS duration. The automatically calculated heart rate is not an accurate measure of true heart rate. The Alivecor KardiaMobile (ECG) device can be considered as a simplified screening ECG device in situations where the more standardised system is either unavailable or impractical, but has some limitations.

摘要

心电图检查是用于监测心脏电冲动的方法。这些诊断方法越来越多地采用基于智能手机的技术。本研究的目的是确定一种新型心电图设备——Alivecor KardiaMobile(心电图)智能手机调制心电图仪,是否可用于获取马的可靠心电图读数。该设备最初在36匹努伊特加赫特矮种马母马身上进行测试,以确定最佳应用部位、皮肤准备方法以及获得可靠心电图描记的心电图仪方向。一旦确定了获取心电图的最可靠部位,便以这种方式将该设备应用于31匹努伊特加赫特矮种马母马,并与标准遥测心电图系统(心电图)进行比较。心电图仪最佳应用于左半胸第四肋间间隙,垂直放置,皮肤用70%乙醇湿润。心电图和心电图之间测定的RR和QT间期平均值无显著差异,然而,两种设备的QRS波群持续时间平均值有显著差异。心电图和心电图设备在PQ、RR和QT间期的测量方面有可接受的一致性,但在QRS波群持续时间方面不一致。自动计算的心率并非真实心率的准确测量值。在更标准化的系统不可用或不实用的情况下,Alivecor KardiaMobile(心电图)设备可被视为一种简化的筛查心电图设备,但存在一些局限性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验