Suppr超能文献

两种折射型分段式和两种衍射型多焦点人工晶状体的多色图像质量比较

Comparison of the Polychromatic Image Quality of Two Refractive-Segmented and Two Diffractive Multifocal Intraocular Lenses.

作者信息

Salvá Luis, García Scott, García-Delpech Salvador, Martínez-Espert Anabel, Montagud-Martínez Diego, Ferrando Vicente

机构信息

Oftalmedic Salvà, 07013 Palma de Mallorca, Spain.

Clínica Aiken, Fundación Aiken, 46004 Valencia, Spain.

出版信息

J Clin Med. 2023 Jul 14;12(14):4678. doi: 10.3390/jcm12144678.

Abstract

Evaluating chromatic aberration for a multifocal intraocular lens (MIOL) in vitro is essential for studying its performance because it helps determine the most appropriate lens for each patient, enhancing surgical outcomes. While refractive MIOLs with angular power variation have shown positive clinical outcomes, studies of these MIOLs on optical benches primarily employed monochromatic green light, neglecting the impact of longitudinal chromatic aberration (LCA) on MIOL performance. To address this gap, we evaluated the through-focus modulation transfer function (TF-MTF) and the point spread function (PSF) of two refractive segmented extended depth of focus intraocular lenses (IOLs) (Femtis Comfort and Precizon Presbyopic), comparing the results with those obtained with two widely known diffractive multifocal intraocular lenses (AcrySof IQ ReSTOR and FineVision Pod F). Measurements of the TF-MTF were conducted using both monochromatic and polychromatic light in a customized optical bench. The refractive designs exhibited distinct haloes in the PSFs. When comparing the refractive and diffractive designs, opposite signs of LCA were observed at near foci. These findings emphasize the influence of the optical design of IOLs on their performance under polychromatic light, providing valuable information for vision care professionals when selecting the most suitable lens for each patient.

摘要

在体外评估多焦点人工晶状体(MIOL)的色差对于研究其性能至关重要,因为这有助于为每位患者确定最合适的晶状体,从而提高手术效果。虽然具有角向光焦度变化的折射型MIOL已显示出积极的临床结果,但在光具座上对这些MIOL的研究主要采用单色绿光,忽略了纵向色差(LCA)对MIOL性能的影响。为了填补这一空白,我们评估了两种折射型分段扩展焦深人工晶状体(IOL)(Femtis Comfort和Precizon Presbyopic)的全聚焦调制传递函数(TF-MTF)和点扩散函数(PSF),并将结果与两种广为人知的衍射型多焦点人工晶状体(AcrySof IQ ReSTOR和FineVision Pod F)的结果进行比较。在定制的光具座上使用单色光和多色光进行TF-MTF的测量。折射设计在PSF中表现出明显的光晕。在比较折射型和衍射型设计时,在近焦点处观察到LCA的符号相反。这些发现强调了IOL光学设计对其在多色光下性能的影响,为视力保健专业人员为每位患者选择最合适的晶状体提供了有价值的信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3aa5/10380361/8823b9fcd922/jcm-12-04678-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验