Suppr超能文献

基于连续过渡焦点的屈光性多焦点人工晶状体所提供的视觉和患者报告结局。

Visual and patient reported outcomes provided by a refractive multifocal intraocular lens based on continuous transitional focus.

作者信息

Alió Jorge L, Martínez-Abad Antonio, Ruiz-Mesa Ramón, Kim Hyo Myung, Mendicute Javier, Ribeiro Filomena J, Holzer Mike P, Cantó-Cerdán Mario

机构信息

Vissum Miranza, Avda de Denia s/n Edificio Vissum, 03016, Alicante, Spain.

Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain.

出版信息

Eye Vis (Lond). 2024 Oct 14;11(1):41. doi: 10.1186/s40662-024-00408-y.

Abstract

PURPOSE

To analyze the quality of vision of patients implanted bilaterally with the multifocal Precizon Presbyopic intraocular lens (IOL), as well as to evaluate the visual performance provided by the lens.

SETTING

Vissum Miranza Alicante.

DESIGN

Prospective multicenter study.

METHODS

56 patients (mean age 65.0 ± 8.7 years old) underwent bilateral implantation with multifocal Precizon Presbyopic IOL. The quality of vision was assessed by a quality of vision questionnaire at 6 months after the implantation procedure, a complete eye examination was also performed including visual and refractive measurements, defocus curve and contrast sensitivity assessment. Visual and refractive variables were compared in preoperative, 3-month postoperative and 6-month postoperative visits by Wilcoxon test.

RESULTS

The quality of vision analysis showed the absence of severe glare and severe haloes in all evaluated patients. Likewise, non-symptoms of glare, haloes and starbursts were seen in 75%, 68%, and 55% of subjects, respectively. Efficacy and safety index was 1.26 and 1.42, respectively. The 6-month postoperative binocular uncorrected distance visual acuity and near uncorrected visual acuity were 0.00 ± 0.09 and 0.20 ± 0.13 logMAR, respectively. Mean spherical equivalent was 0.29 ± 0.45 D.

CONCLUSIONS

The Precizon Presbyopic NVA IOL (OPHTEC BV) provides a suitable quality of vision with a low rate of disturbance photic phenomena induction, as well as an excellent visual performance at main distances of sight accomplishing the visual demands of the majority of patients.

摘要

目的

分析双侧植入多焦点Precizon老视人工晶状体(IOL)患者的视觉质量,并评估该晶状体提供的视觉性能。

设置

阿利坎特Vissum Miranza。

设计

前瞻性多中心研究。

方法

56例患者(平均年龄65.0±8.7岁)接受了双侧多焦点Precizon老视IOL植入术。在植入手术后6个月,通过视觉质量问卷评估视觉质量,还进行了全面的眼部检查,包括视力和屈光测量、散焦曲线和对比敏感度评估。通过Wilcoxon检验比较术前、术后3个月和术后6个月就诊时的视力和屈光变量。

结果

视觉质量分析显示,所有评估患者均未出现严重眩光和严重光晕。同样,分别有75%、68%和55%的受试者未出现眩光、光晕和星芒症状。有效性和安全性指数分别为1.26和1.42。术后6个月的双眼未矫正远视力和近未矫正视力分别为0.00±0.09和0.20±0.13 logMAR。平均球镜等效度为0.29±0.45 D。

结论

Precizon老视NVA IOL(OPHTEC BV)提供了合适的视觉质量,诱导光干扰现象的发生率较低,并且在主要视距处具有出色的视觉性能,满足了大多数患者的视觉需求。