Suppr超能文献

干热法作为N95口罩重复使用的去污方法

Dry Heat as a Decontamination Method for N95 Respirator Reuse.

作者信息

Oh Chamteut, Araud Elbashir, Puthussery Joseph V, Bai Hezi, Clark Gemma G, Wang Leyi, Verma Vishal, Nguyen Thanh H

机构信息

Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.

Holonyak Micro & Nanotechnology Lab, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.

出版信息

Environ Sci Technol Lett. 2020 Jul 15;7(9):677-682. doi: 10.1021/acs.estlett.0c00534. eCollection 2020 Sep 8.

Abstract

A pandemic such as COVID-19 can cause a sudden depletion of the worldwide supply of respirators, forcing healthcare providers to reuse them. In this study, we systematically evaluated dry heat treatment as a viable option for the safe decontamination of N95 respirators (1860, 3M) before their reuse. We found that the dry heat generated by an electric cooker (100 °C, 5% relative humidity, 50 min) effectively inactivated Tulane virus (TV, >5.2-log reduction), rotavirus (RV, >6.6-log reduction), adenovirus (AdV, >4.0-log reduction), and transmissible gastroenteritis virus (TGEV, >4.7-log reduction). The respirator integrity (determined on the basis of the particle filtration efficiency and quantitative fit testing) was not compromised after 20 cycles of a 50 min dry heat treatment. On the basis of these results, dry heat decontamination generated by an electric cooker (e.g., rice cookers, instant pots, and ovens) could be an effective and accessible decontamination method for the safe reuse of N95 respirators. We recommend users measure the temperature during decontamination to ensure the respirator temperature can be maintained at 100 °C for 50 min.

摘要

像COVID-19这样的大流行病可能会导致全球范围内呼吸器供应的突然短缺,迫使医疗保健提供者重复使用它们。在本研究中,我们系统地评估了干热处理作为N95呼吸器(1860,3M)在重复使用前进行安全消毒的可行选择。我们发现,电饭锅产生的干热(100°C,相对湿度5%,50分钟)有效地灭活了杜兰病毒(TV,>5.2对数减少)、轮状病毒(RV,>6.6对数减少)、腺病毒(AdV,>4.0对数减少)和传染性胃肠炎病毒(TGEV,>4.7对数减少)。在进行20个周期的50分钟干热处理后,呼吸器的完整性(根据颗粒过滤效率和定量适合性测试确定)没有受到损害。基于这些结果,电饭锅(如电饭煲、电压力锅和烤箱)产生的干热消毒可能是一种有效且易于获得的消毒方法,可用于N95呼吸器的安全重复使用。我们建议用户在消毒过程中测量温度,以确保呼吸器温度能保持在100°C达50分钟。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验