An isoelastic monoblock cup versus a modular metal-back cup: a matched-pair analysis of clinical and radiological results using Einzel-Bild-Röntgen-Analyse software.

机构信息

Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany.

Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany.

出版信息

Arch Orthop Trauma Surg. 2024 Jan;144(1):493-500. doi: 10.1007/s00402-023-05058-8. Epub 2023 Sep 23.

Abstract

INTRODUCTION

Bone preservation and long-term survival are the main challenges in cementless total hip arthroplasty (THA). A good bone stock is especially important for adequate anchorage of the cup in revision cases. However, the optimal acetabular cup design for preserving good bone stock is still unclear. We aimed to compare clinical outcome, radiological alterations, migration, and wear at mid-term for two different cup types.

MATERIALS AND METHODS

This retrospective matched-pair study was performed using the data for 98 THA cases treated with a monoblock cup composed of vitamin E-blended highly cross-linked polyethylene (VEPE; monoblock group) or a modular cup composed of a highly cross-linked polyethylene (HXLPE) without an antioxidant (modular group). Clinical results were evaluated using the Harris Hip Score (HHS). The obtained radiographs were analyzed for radiological alterations, migration, and wear using Einzel-Bild-Röntgen-Analyse (EBRA) software.

RESULTS

The mean follow-up duration was 73.2 ± 19.2 months (range: 32-108 months) and 60.5 ± 12.2 months (range: 20-84 months) in the monoblock and modular groups, respectively. HHS improved to 95.7 points in the monoblock group and 97.6 points in the modular group, without significant differences (p = 0.425). EBRA measurements were obtained in all cases. Acetabular bone alterations were not detected on radiological assessments. Mean cup migration was 1.67 ± 0.92 mm (range: 0.46-3.94 mm) and 1.24 ± 0.87 mm (range: 0.22-3.62 mm) in the monoblock and modular groups. The mean wear rate was 0.21 ± 0.18 mm (range: 0.00-0.70 mm) and 0.20 ± 0.13 mm (range: 0.00-0.50 mm) in the monoblock and modular groups. Both migration and wear pattern showed no significant differences (p = 0.741 and 0.243). None of the cases required revision surgery, yielding an implant survival rate of 100% in both groups.

CONCLUSION

The isoelastic press-fit monoblock VEPE cup and modular metal-back HXLPE cup showed equivalent mid-term wear and cup migration. Long-term studies are required to determine the effects of modularity, isoelasticity, and polyethylene stabilization with vitamin E on cup loosening and survival rates.

摘要

简介

在非骨水泥全髋关节置换术(THA)中,骨保存和长期生存是主要挑战。对于翻修病例,良好的骨质是确保杯具充分固定的关键。然而,目前仍不清楚哪种髋臼杯设计最有利于保留良好的骨质。本研究旨在比较两种不同杯具类型的中期临床结果、影像学改变、迁移和磨损情况。

材料与方法

本回顾性配对研究使用了采用维生素 E 共混高交联聚乙烯(VEPE)制成的单体杯(单体组)或不含抗氧化剂的高交联聚乙烯(HXLPE)制成的模块杯(模块组)治疗的 98 例 THA 病例的数据。临床结果采用 Harris 髋关节评分(HHS)进行评估。使用 Einzel-Bild-Röntgen-Analyse(EBRA)软件对获得的 X 线片进行影像学改变、迁移和磨损分析。

结果

单体组和模块组的平均随访时间分别为 73.2±19.2 个月(范围:32-108 个月)和 60.5±12.2 个月(范围:20-84 个月)。单体组 HHS 改善至 95.7 分,模块组改善至 97.6 分,差异无统计学意义(p=0.425)。所有病例均获得 EBRA 测量值。影像学评估未发现髋臼骨改变。平均杯具迁移分别为 1.67±0.92mm(范围:0.46-3.94mm)和 1.24±0.87mm(范围:0.22-3.62mm)。平均磨损率分别为 0.21±0.18mm(范围:0.00-0.70mm)和 0.20±0.13mm(范围:0.00-0.50mm)。迁移和磨损模式均无显著差异(p=0.741 和 0.243)。两组均无需翻修手术,植入物生存率均为 100%。

结论

等弹性压配单体 VEPE 杯和模块式金属背 HXLPE 杯具有相似的中期磨损和杯具迁移情况。需要进行长期研究以确定模块性、等弹性和维生素 E 对聚乙烯稳定性的影响对杯松动和生存率的影响。