Suppr超能文献

韩国流通的动物源加工食品中胭脂树素和降胭脂树素的验证、测量不确定度及测定

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea.

作者信息

Lee Ga-Yeong, Yun Choong-In, Cho Juhee, Kim Young-Jun

机构信息

Department of Food Science and Biotechnology, Seoul National University of Science and Technology, Seoul 01811, Korea.

Research Institute of Food and Biotechnology, Seoul National University of Science and Technology, Seoul 01811, Korea.

出版信息

Food Sci Anim Resour. 2023 Nov;43(6):949-960. doi: 10.5851/kosfa.2023.e49. Epub 2023 Nov 1.

Abstract

This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra- and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.

摘要

本研究旨在验证一种用于定量测定各类食品中胭脂树橙和降胭脂树橙的高效液相色谱法。采用二极管阵列检测器(495 nm)技术。对该方法的特异性、线性、检测限(LOD)、定量限(LOQ)、精密度和准确度进行了验证,并评估了测量不确定度。校准曲线在0.2 - 25 mg/L的测试浓度范围内显示出良好的线性(r≥0.9999)。胭脂树橙和降胭脂树橙的检测限分别为0.03 - 0.11和0.02 - 0.05 mg/L,定量限分别为0.02 - 0.05和0.03 - 0.11 mg/L。胭脂树橙的日内和日间准确度及精密度分别为88.0±1.3 - 97.0±0.5%和0.2% - 2.6%相对标准偏差(RSD),降胭脂树橙的日内和日间准确度及精密度分别为88.2±0.8 - 105.8±0.8%和0.3% - 2.7% RSD。在三个实验室进行了实验室间准确度和精密度验证,这些结果均符合AOAC指南。此外,相对扩展不确定度(<22%)满足食品法典委员会的建议。此外,使用所提出的方法对韩国市场上销售的产品中的胭脂树提取物进行了监测,以证明其应用。所建立的分析方法对于定量测定各类食品中的胭脂树橙和降胭脂树橙是可靠的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验