Suppr超能文献

自动输血压力控制系统在血液回收中的应用。

Application of an autotransfusion pressure control system in blood salvage.

机构信息

Department of Anesthesiology, People's Hospital of Lishui, Lishui, Zhejiang, China.

Department of Anesthesiology, People's Hospital of Haiyan, Haiyan, Zhejiang, China.

出版信息

J Int Med Res. 2023 Nov;51(11):3000605231206963. doi: 10.1177/03000605231206963.

Abstract

OBJECTIVE

This study was performed to evaluate the effect of a homemade autotransfusion pressure-control system on the regulation of negative pressure and to clarify the influence of different negative pressures on the recovered erythrocytes.

METHODS

Fifty patients were randomly divided into five groups, and five different suction-generated negative pressures were applied. Before suction, 6 mL of blood was collected from the surgical field; after suction, 6 mL of blood was collected from the blood storage tank. The hemoglobin, hematocrit, mean corpuscular volume, newly generated standardized plasma free hemoglobin, and change in the hemolysis rate of erythrocytes before and after suction were compared. Additionally, the erythrocyte morphology was observed.

RESULTS

The hemoglobin and hematocrit were significantly different before and after suction in all five groups. As the suction pressure increased, gradual increases were noted in the number of abnormal erythrocytes in the field of view, the newly generated standardized plasma free hemoglobin, and the change in the hemolysis rate.

CONCLUSIONS

The destruction rate of erythrocytes increased as the suction-generated negative pressure increased. When using a pressure-control system, a negative pressure of <200 mmHg should be applied to reduce the damage to the autotransfused blood.

摘要

目的

本研究旨在评估自制自体输血压力控制系统对负压调节的影响,并阐明不同负压对回收红细胞的影响。

方法

将 50 例患者随机分为 5 组,应用 5 种不同的负压吸引。吸引前从手术部位采集 6mL 血液,吸引后从储血罐采集 6mL 血液。比较吸引前后血红蛋白、血细胞比容、平均红细胞体积、新生成的标准化血浆游离血红蛋白以及红细胞溶血率的变化。此外,还观察了红细胞形态。

结果

所有 5 组在吸引前后血红蛋白和血细胞比容均有显著差异。随着吸引压力的增加,视野中异常红细胞的数量、新生成的标准化血浆游离血红蛋白以及溶血率的变化逐渐增加。

结论

随着负压的增加,红细胞的破坏率增加。使用压力控制系统时,应施加负压<200mmHg,以减少对自体输血的损害。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1195/10686018/1299c45420e0/10.1177_03000605231206963-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验