Adams A P, Freedman A, Dart J K
Anaesthesia. 1979 Jun;34(6):526-33. doi: 10.1111/j.1365-2044.1979.tb06336.x.
Measurements of intraocular pressure (IOP) by applanation tonometry in twelve patients undergoing lens extraction showed that a normocapnic anaesthetic technique using 0.4% trichloroethylene with controlled ventilation of the lungs (IPPV) with large tidal volumes (14 ml/kg) reduced IOP by 13--20%. There was only a small reduction in arterial pressure. Normocapnia was easy to achieve by use of the single-limb co-axial Penlon (Bain type) anaesthetic breathing circuit in conjunction with an electrically-driven, small and inexpensive lung ventilator. The anaesthetic technique described using trichloroethylene is suitable for lens extraction surgery when it is desired to avoid a halothane anaesthetic for any reason.