Department of Rehabilitation, Mutua Montañesa Hospital, Santander, Cantabria, Spain.
Department of Nursing, Universidad de Cantabria, Santander, Cantabria, Spain.
J Orthop Surg Res. 2024 Apr 22;19(1):256. doi: 10.1186/s13018-024-04723-x.
The Michigan Hand Outcomes Questionnaire (MHQ) is a self-report tool widely recognized for measuring the health status of patients with hand and wrist problems from a multidimensional perspective. The aim of this study is to translate and culturally adapt the MHQ and validate its psychometric properties of validity, reliability, and responsiveness for different hand problems in Spain.
The MHQ was translated and culturally adapted following the recommendations of the American Association of Orthopaedic Surgeons. The validation process adhered to the current Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) group and was conducted on 262 hand patients. Reliability was assessed through internal consistency using Cronbach's alpha. The study evaluated the test-retest reliability of the measurements using the intraclass correlation coefficient (ICC). Additionally, the measurement error was calculated using the standard error of measurement (SEM) and smallest detectable change (SDC). To assess the structural validity, confirmatory factor analysis (CFA) was employed, while construct validity was evaluated using Pearson's correlation coefficient. Finally, responsiveness was assessed using effect size (ES), standardized response mean (SRM), and minimum clinically important difference (MCID).
The reliability of the test was confirmed through internal consistency analysis, with a good Crombach's Alpha (0.82-0.85), and test-retest analysis, with good values of ICC (0.74-0.91). The measurement error was also assessed, with low values of SEM (1.70-4.67) and SDC (4.71-12.94)). The CFA confirmed the unidimensionality of each scale with goodness of fit indices, while the MHQ showed a high and negative correlation with DASH (r = - 0.75, P < 0.001) and DASH-work (r = - 0.63, P < 0.001) and was irrelevant with EQ-5D (r = - 0.01, P > 0.005) and grip strength (r = 0.05, P > 0.005). At week 5, all 222 patients across the three diagnosed hand subgroups showed moderate to high values above 0.92 for ES and SRM, with one MCID above 6.85.
The MHQ-Sp was culturally adapted, and the results of this version showed good reliability and validity as well as high responsiveness for a wide range of hand conditions after surgical or conservative treatment in Spain.
密歇根手部问卷(MHQ)是一种自我报告工具,从多维角度广泛用于衡量手部和腕部问题患者的健康状况。本研究的目的是翻译和文化适应 MHQ,并验证其在西班牙不同手部问题中的有效性、可靠性和反应度的心理测量学特性。
MHQ 按照美国矫形外科医师协会的建议进行翻译和文化适应。验证过程遵循当前基于共识的健康状况测量仪器选择标准(COSMIN)小组的建议,并对 262 名手部患者进行了评估。通过 Cronbach's alpha 进行内部一致性评估来评估可靠性。使用组内相关系数(ICC)评估测量的重测信度。此外,通过测量误差(SEM)和最小可检测变化(SDC)计算测量误差。为了评估结构有效性,使用验证性因子分析(CFA),而使用 Pearson 相关系数评估结构有效性。最后,使用效应量(ES)、标准化反应均值(SRM)和最小临床重要差异(MCID)评估反应度。
通过内部一致性分析确认了测试的可靠性,Crombach's Alpha 值良好(0.82-0.85),通过测试-再测试分析,ICC 值良好(0.74-0.91)。还评估了测量误差,SEM 值较低(1.70-4.67),SDC 值较低(4.71-12.94)。CFA 证实了每个量表的一维性,拟合指标良好,而 MHQ 与 DASH(r = -0.75,P < 0.001)和 DASH-work(r = -0.63,P < 0.001)呈高度负相关,与 EQ-5D(r = -0.01,P > 0.005)和握力(r = 0.05,P > 0.005)无关。在第 5 周,三个诊断手部亚组的所有 222 名患者的 ES 和 SRM 值均超过 0.92,表现出中度至高度的反应度,其中一个 MCID 值超过 6.85。
MHQ-Sp 经过文化适应,该版本的结果显示出良好的可靠性和有效性,以及在西班牙经过手术或保守治疗后广泛的手部疾病的高反应性。