超声心动图检查时背部心电图电极的放置:一项探索性横断面研究

Electrocardiogram Electrode Positioning on the Back During Echocardiography: An Exploratory Cross-Sectional Study.

作者信息

Yamashita Satoshi, Saitoh Takeji, Iguchi Keisuke, Suwa Kenichiro, Ohtani Hayato, Saotome Masao, Maekawa Yuichiro

机构信息

Department of Cardiology, Hamamatsu University School of Medicine, Hamamatsu, JPN.

Next Generation Creative Education Center for Medicine, Engineering, and Informatics, Hamamatsu University School of Medicine, Hamamatsu, JPN.

出版信息

Cureus. 2024 Apr 10;16(4):e57967. doi: 10.7759/cureus.57967. eCollection 2024 Apr.

Abstract

BACKGROUND

ECG interpretation is sometimes difficult due to baseline fluctuations and electrode detachments when placed on the subjects' front side, leading to misinterpretation of the rhythms and phases of the cardiac cycle. We aimed to compare the differences in the wave amplitudes and respiratory variations between conventional ECG electrode positioning on the front side of patients and an alternative position on the backs of patients.

METHODS

Echocardiography was performed in 85 patients lying in the left lateral position. We attached the red electrode to the right clavicle, the yellow to the left clavicle, and the green to the left lateral abdomen on the front side of the patients; on the back, we attached the electrode to the right clavicle, the right upper posterior iliac spine, and the left upper posterior iliac spine.

RESULTS

The ECG monitor amplitudes were greater on the front side compared to the back side, but the BF-breath values were smaller on the back side (6.0 pixels) compared to the front side (10.5 pixels, p<0.05). The P wave amplitude divided by the BF-breath on the back side was greater than that seen on the front side (2.8 vs. 1.8, p<0.05), whereas the QRS amplitude divided by the BF-breath was 15.0 and 16.3, respectively (p=ns).

CONCLUSION

As an alternative to front-side ECG monitoring, electrodes placed on the back can help avoid misinterpretation of the ECG rhythms and the phases of the cardiac cycle due to respiration during echocardiography.

摘要

背景

当将心电图电极放置在受试者身体前侧时,由于基线波动和电极脱落,心电图解读有时会很困难,这会导致对心动周期的节律和阶段产生错误解读。我们旨在比较患者身体前侧传统心电图电极定位与身体后侧替代定位之间的波幅和呼吸变化差异。

方法

对85例左侧卧位的患者进行了超声心动图检查。我们将红色电极贴在患者身体前侧的右锁骨处,黄色电极贴在左锁骨处,绿色电极贴在左下腹;在身体后侧,我们将电极贴在右锁骨处、右髂后上棘和左髂后上棘。

结果

与身体后侧相比,心电图监测器在前侧的波幅更大,但身体后侧的BF-呼吸值(6.0像素)比前侧(10.5像素)小(p<0.05)。身体后侧P波幅除以BF-呼吸的值大于前侧(2.8对1.8,p<0.05),而QRS波幅除以BF-呼吸的值分别为15.0和16.3(p=无显著性差异)。

结论

作为身体前侧心电图监测的替代方法,放置在身体后侧的电极有助于避免在超声心动图检查期间因呼吸导致的心电图节律和心动周期阶段的错误解读。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f0c2/11086598/955798ccb767/cureus-0016-00000057967-i01.jpg

相似文献

2
Effect of the recording condition on the quality of a single-lead electrocardiogram.记录条件对单导联心电图质量的影响。
Heart Vessels. 2022 Jun;37(6):1010-1026. doi: 10.1007/s00380-021-01991-z. Epub 2021 Dec 2.
3
[An improved method of electrode placement for ECG monitoring in children].
Zhongguo Dang Dai Er Ke Za Zhi. 2015 Sep;17(9):975-9.
6
Effects of limb electrode placement on the 12- and 16-lead electrocardiogram.肢体电极放置对12导联和16导联心电图的影响。
J Electrocardiol. 2008 Nov-Dec;41(6):536-45. doi: 10.1016/j.jelectrocard.2008.07.023. Epub 2008 Sep 13.

本文引用的文献

1
Electrocardiogram Derived Respiratory Rate Using a Wearable Armband.基于可穿戴臂带的心电图呼吸频率检测。
IEEE Trans Biomed Eng. 2021 Mar;68(3):1056-1065. doi: 10.1109/TBME.2020.3004730. Epub 2021 Feb 18.
3
Congenital defects of the pericardium: a review.先天性心包缺陷:综述。
Eur Heart J Cardiovasc Imaging. 2015 Aug;16(8):821-7. doi: 10.1093/ehjci/jev119. Epub 2015 May 23.
5
Electrocardiogram derived respiratory rate from QRS slopes and R-wave angle.基于QRS波斜率和R波角度的心电图衍生呼吸率
Ann Biomed Eng. 2014 Oct;42(10):2072-83. doi: 10.1007/s10439-014-1073-x. Epub 2014 Aug 14.
6
Prognostic markers for acute heart failure.
Expert Opin Med Diagn. 2013 Jul;7(4):379-92. doi: 10.1517/17530059.2013.814638.
10
Mechanics of respiratory muscles.呼吸肌的力学原理。
Respir Physiol Neurobiol. 2008 Nov 30;163(1-3):82-9. doi: 10.1016/j.resp.2008.04.019. Epub 2008 May 15.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验