Yamashita Satoshi, Saitoh Takeji, Iguchi Keisuke, Suwa Kenichiro, Ohtani Hayato, Saotome Masao, Maekawa Yuichiro
Department of Cardiology, Hamamatsu University School of Medicine, Hamamatsu, JPN.
Next Generation Creative Education Center for Medicine, Engineering, and Informatics, Hamamatsu University School of Medicine, Hamamatsu, JPN.
Cureus. 2024 Apr 10;16(4):e57967. doi: 10.7759/cureus.57967. eCollection 2024 Apr.
ECG interpretation is sometimes difficult due to baseline fluctuations and electrode detachments when placed on the subjects' front side, leading to misinterpretation of the rhythms and phases of the cardiac cycle. We aimed to compare the differences in the wave amplitudes and respiratory variations between conventional ECG electrode positioning on the front side of patients and an alternative position on the backs of patients.
Echocardiography was performed in 85 patients lying in the left lateral position. We attached the red electrode to the right clavicle, the yellow to the left clavicle, and the green to the left lateral abdomen on the front side of the patients; on the back, we attached the electrode to the right clavicle, the right upper posterior iliac spine, and the left upper posterior iliac spine.
The ECG monitor amplitudes were greater on the front side compared to the back side, but the BF-breath values were smaller on the back side (6.0 pixels) compared to the front side (10.5 pixels, p<0.05). The P wave amplitude divided by the BF-breath on the back side was greater than that seen on the front side (2.8 vs. 1.8, p<0.05), whereas the QRS amplitude divided by the BF-breath was 15.0 and 16.3, respectively (p=ns).
As an alternative to front-side ECG monitoring, electrodes placed on the back can help avoid misinterpretation of the ECG rhythms and the phases of the cardiac cycle due to respiration during echocardiography.
当将心电图电极放置在受试者身体前侧时,由于基线波动和电极脱落,心电图解读有时会很困难,这会导致对心动周期的节律和阶段产生错误解读。我们旨在比较患者身体前侧传统心电图电极定位与身体后侧替代定位之间的波幅和呼吸变化差异。
对85例左侧卧位的患者进行了超声心动图检查。我们将红色电极贴在患者身体前侧的右锁骨处,黄色电极贴在左锁骨处,绿色电极贴在左下腹;在身体后侧,我们将电极贴在右锁骨处、右髂后上棘和左髂后上棘。
与身体后侧相比,心电图监测器在前侧的波幅更大,但身体后侧的BF-呼吸值(6.0像素)比前侧(10.5像素)小(p<0.05)。身体后侧P波幅除以BF-呼吸的值大于前侧(2.8对1.8,p<0.05),而QRS波幅除以BF-呼吸的值分别为15.0和16.3(p=无显著性差异)。
作为身体前侧心电图监测的替代方法,放置在身体后侧的电极有助于避免在超声心动图检查期间因呼吸导致的心电图节律和心动周期阶段的错误解读。