Rødahl E
Acta Pathol Microbiol Immunol Scand C. 1985 Jun;93(3):125-30. doi: 10.1111/j.1699-0463.1985.tb02933.x.
In the application of the anti-Clq, the anti-C3, or the conglutinin-binding assay for the detection of complement-fixing circulation immune complexes in patients with ankylosing spondylitis or healthy blood donors, antibodies cross-reacting with the solid-phase bound agent were observed in several sera, resulting in erroneous interpretation of the tests. Corrections for the interfering antibodies were made by testing for the binding to conglutinin both in the presence and in the absence of Ca++, while the anti-Clq and the anti-C3 assays included the application of F(ab')2 fragments of normal IgG to check for anti-F(ab)2 anti-bodies.
在应用抗Clq、抗C3或胶固素结合试验检测强直性脊柱炎患者或健康献血者体内补体结合循环免疫复合物时,在几份血清中观察到与固相结合剂发生交叉反应的抗体,导致对检测结果的错误解读。通过在有Ca++和无Ca++的情况下检测与胶固素的结合来校正干扰抗体,而抗Clq和抗C3试验则应用正常IgG的F(ab')2片段来检查抗F(ab)2抗体。