Suppr超能文献

钢板设计对内侧开放楔形高位胫骨截骨术后循环加载下前后间隙及胫骨后倾坡度维持的影响:一项使用猪胫骨的生物力学研究

Effect of plate design on maintenance of anterior and posterior gaps and posterior tibial slope after cyclic loading in medial open-wedge high tibial osteotomy: A biomechanical study using porcine's tibia.

作者信息

Nibe Yoshiya, Takahashi Tsuneari, Matsumura Tomohiro, Kubo Tatsuya, Takeshita Katsushi

机构信息

Department of Orthopaedic Surgery, School of Medicine Jichi Medical University Shimotsuke Japan.

Department of Orthopaedic Surgery Ishibashi General Hospital Shimotsuke Japan.

出版信息

J Exp Orthop. 2024 Jun 19;11(3):e12036. doi: 10.1002/jeo2.12036. eCollection 2024 Jul.

Abstract

PURPOSE

We aimed to investigate whether a plate adapted to the anatomy of the proximal medial porcine's tibia would provide maintenance of the anterior gap (AG), posterior gap (PG) and posterior tibial slope (PTS).

METHODS

Twenty-seven porcine tibias were biomechanically evaluated by performing MOWHTO and placing TOMOFIX ( = 9), AC plate ( = 9) and TriS ( = 9) anteromedially. Cyclic testing (800 N, 2000 cycles, 0.5 Hz) was performed to investigate the PTS over time for MOWHTO. The particular displacement calculated from the maximum to the minimum point with the load-displacement curve along the mechanical axis during cyclic testing, the final AG and PG changes at the osteotomy site, the increased PTS calculated by subtracting AG from PG after 2000 cycles were compared among the three groups. The displacement was evaluated by repeated-measures analysis of variance (ANOVA), and changes in AG and PG and increased PTS were evaluated by one-way ANOVA. The sample size for and errors were <0.05 and <0.20, and the effect size was 0.64 for one-way ANOVA and 0.49 for repeated-measures ANOVA.

RESULTS

There were no significant differences in displacement among the groups. A significant difference was observed in the AG ( = 0.044) and PG ( = 0.0085) changes. There were no significant differences in increased PTS among the groups.

CONCLUSION

When anteromedially placed, the AC plate and TriS resulted in significant maintenance of AG and PG compared with that of TOMOFIX in MOWHTO after cyclic loading.

LEVEL OF EVIDENCE

Level Ⅳ.

摘要

目的

我们旨在研究一种适配猪胫骨近端内侧解剖结构的接骨板是否能维持前间隙(AG)、后间隙(PG)和胫骨后倾坡度(PTS)。

方法

对27根猪胫骨进行微创开放性楔形高位胫骨截骨术(MOWHTO)并在内侧前方放置TOMOFIX接骨板(n = 9)、AC接骨板(n = 9)和TriS接骨板(n = 9),然后进行生物力学评估。进行循环测试(800 N,2000次循环,0.5 Hz)以研究MOWHTO术后不同时间的PTS。比较三组在循环测试期间沿机械轴的载荷 - 位移曲线从最大点到最小点计算的特定位移、截骨部位最终的AG和PG变化、2000次循环后通过PG减去AG计算出的PTS增加量。位移通过重复测量方差分析(ANOVA)进行评估,AG和PG的变化以及PTS增加量通过单因素ANOVA进行评估。单向ANOVA的样本量和误差分别<0.05和<0.20,效应量为0.64;重复测量ANOVA的效应量为0.49。

结果

各组之间的位移无显著差异。观察到AG(P = 0.044)和PG(P = 0.0085)变化存在显著差异。各组之间PTS增加量无显著差异。

结论

在内侧前方放置时,与TOMOFIX接骨板相比,AC接骨板和TriS接骨板在循环加载后的MOWHTO中能显著维持AG和PG。

证据水平

Ⅳ级。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3c5f/11185942/7b2676ac70f6/JEO2-11-e12036-g007.jpg