Suppr超能文献

雅典失眠量表在高海拔环境下中国年轻男性人群中的效度验证

Validation of the Athens Insomnia Scale Among Young Chinese Male Population in a High-Altitude Situation.

作者信息

Tang Xugang, Wang Qiang, Li Shuang, Li Xiuchuan, Xin Qian, Yang Yongjian

机构信息

Department of Cardiology, The General Hospital of Western Theater Command, Chengdu, Sichuan, People's Republic of China.

Department of Cardiology, The Sixth Medical Center of Chinese PLA General Hospital, Beijing, People's Republic of China.

出版信息

Nat Sci Sleep. 2024 Sep 17;16:1377-1386. doi: 10.2147/NSS.S475497. eCollection 2024.

Abstract

PURPOSE

The Athens Insomnia Scale (AIS) is a widely used and authorized questionnaire for evaluating insomnia symptoms. However, its reliability and validity at high altitudes are uncertain. Therefore, this study aimed to confirm the validity and reliability of AIS during a 3658 m altitude exposure.

PATIENTS AND METHODS

A total of 387 young Chinese males were enlisted in the acute high-altitude exposure group. They flew for about two hours, climbing from 400 m to 3658 m. The high-altitude-acclimated group consisted of 86 young Chinese men who had lived at least six months at 3658 m altitude. The sleep quality of the acute high-altitude exposure group was evaluated using the AIS before the ascent and after exposure to 3658 m for 24 hours, and one week. The sleep quality of the high-altitude-acclimated group was also assessed. The AIS's internal consistency, reliability, and validity were evaluated.

RESULTS

The respondents' quality of sleep significantly decreased after being exposed to 3658 m as opposed to 400 m. Two factors comprised the AIS, according to an exploratory factor analysis: "sleep problem" (items 1-5) and "daytime dysfunction" (items 6-8). The Cronbach's α internal consistency coefficients exceeded 0.8, and the corrected item-total correlations were all greater than 0.5 when the subjects were exposed to 3658 m. The model fit index was well within the criterion. The average variance extracted and composite reliability were all higher than 0.5 and 0.7, respectively. The interclass correlation coefficient was deemed "fair to good" at 0.482, which is greater than the 0.4 threshold. The AIS has satisfactory discriminant validity, as shown by the Fornell-Larcker criterion and cross-loading results. The daytime dysfunction R-square values (>0.33) show that the frameworks have considerable predictive accuracy.

CONCLUSION

The AIS exhibits strong consistency, reliability, and validity. The AIS's features and simplicity make it an essential psychometric tool for high-altitude sleep research.

摘要

目的

雅典失眠量表(AIS)是一种广泛使用且经过授权的用于评估失眠症状的问卷。然而,其在高海拔地区的可靠性和有效性尚不确定。因此,本研究旨在确认AIS在海拔3658米暴露期间的有效性和可靠性。

患者与方法

共有387名中国年轻男性被纳入急性高海拔暴露组。他们飞行了约两小时,从400米攀升至3658米。高海拔适应组由86名在中国年轻男性组成,他们在海拔3658米处生活了至少六个月。急性高海拔暴露组的睡眠质量在 ascent之前以及暴露于3658米24小时和一周后使用AIS进行评估。高海拔适应组的睡眠质量也进行了评估。对AIS的内部一致性、可靠性和有效性进行了评估。

结果

与400米相比,暴露于3658米后,受访者的睡眠质量显著下降。根据探索性因素分析,AIS由两个因素组成:“睡眠问题”(项目1 - 5)和“日间功能障碍”(项目6 - 8)。当受试者暴露于3658米时,克朗巴哈α内部一致性系数超过0.8,校正后的项目 - 总分相关性均大于0.5。模型拟合指数完全在标准范围内。平均方差抽取量和组合信度分别高于0.5和0.7。组内相关系数为0.482,被认为“中等至良好”,大于0.4的阈值。如Fornell - Larcker准则和交叉负荷结果所示,AIS具有令人满意的区分效度。日间功能障碍的R平方值(>0.33)表明该框架具有相当高的预测准确性。

结论

AIS表现出很强的一致性、可靠性和有效性。AIS的特点和简便性使其成为高海拔睡眠研究的重要心理测量工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/95a9/11416112/37fc0feb556c/NSS-16-1377-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验