This article reports a row-column (RC) addressed flexible piezoelectric micromachined ultrasound transducer (PMUT) array with a top-down fabrication process. The fabrication uses a temporary carrier wafer from which the array device is released by deep reactive ion etching (DRIE). About 0.8- m-thick sol-gel processed lead zirconate titanate (PZT) thin film acts as the active piezoelectric. The flexible PMUT membrane includes the PZT film and a 14- m polyimide as a passive layer. A sidewall made of polyimide measuring m in thickness with a cavity of m in diameter is realized by reactive ion etching (RIE). Laser Doppler vibrometer (LDV) characterization of the PMUT indicates 2.7 and 2.1 MHz as the resonance frequency in-air and underwater, respectively. Excitation of a single PMUT element coupled with 5-V direct current (dc) bias results in 1.2-nm/V sensitivity in-air, whereas when the same is excited along with 10-V dc bias, a pressure response of 40 Pa/V at 1 cm is measured underwater using a hydrophone. The presented results under bending to an 8-mm bending radius show the potential for wearable applications in shallow-depth regions subject to further optimization.
本文报道了一种采用自上而下制造工艺的行列(RC)寻址柔性压电微机械超声换能器(PMUT)阵列。该制造过程使用了一个临时载体晶圆,通过深反应离子刻蚀(DRIE)从该晶圆上释放阵列器件。约0.8微米厚的溶胶-凝胶法制备的锆钛酸铅(PZT)薄膜作为有源压电材料。柔性PMUT膜包括PZT膜和作为无源层的14微米厚的聚酰亚胺。通过反应离子刻蚀(RIE)实现了由厚度为微米、直径为微米的腔的聚酰亚胺制成的侧壁。PMUT的激光多普勒振动计(LDV)表征表明,在空气中和水下的共振频率分别为2.7兆赫和2.1兆赫。单个PMUT元件在5伏直流(dc)偏置下的激励在空气中产生1.2纳米/伏的灵敏度,而当在10伏直流偏置下进行相同激励时,使用水听器在水下1厘米处测得的压力响应为40帕/伏。在弯曲至8毫米弯曲半径的情况下给出的结果表明,在浅深度区域的可穿戴应用具有进一步优化的潜力。