Suppr超能文献

青光眼患者视网膜神经纤维层与布鲁赫膜开口-最小视盘边缘宽度厚度之间差异的来源。

Sources of Discrepancy between Retinal Nerve Fiber Layer and Bruch's Membrane Opening-Minimum Rim Width Thickness in Eyes with Glaucoma.

作者信息

Zhuang Iris, Ashrafkhorasani Maryam, Mohammadzadeh Vahid, Nouri-Mahdavi Kouros

机构信息

Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California.

出版信息

Ophthalmol Sci. 2024 Aug 22;5(1):100601. doi: 10.1016/j.xops.2024.100601. eCollection 2025 Jan-Feb.

Abstract

PURPOSE

To compare the discrepancies between circumpapillary retinal nerve fiber layer (RNFL) and Bruch's membrane opening-minimum rim width (BMO-MRW) thickness in glaucoma eyes.

DESIGN

A cross-sectional observational study.

SUBJECTS

One hundred eighty-six eyes (118 patients) with glaucoma.

METHODS

OCT optic nerve head volume scans of patients enrolled in the Advanced Glaucoma Progression Study at the final available visit were exported. The RNFL and BMO-MRW measurements were averaged into corresponding 7.5° sectors, and the nasal sector data were excluded from analyses. A 2-stage screening process was used to identify true mismatches between the RNFL and BMO-MRW measurements, in which either the RNFL or BMO-MRW value was in the less than first percentile range while its counterpart was in the greater than first percentile range on the temporal-superior-nasal-inferior-temporal curve. The prevalence of these mismatches was mapped, and corresponding images were reviewed to determine the underlying cause of these discrepancies.

MAIN OUTCOME MEASURES

Proportion of mismatches between RNFL and BMO-MRW, location of mismatches between RNFL and BMO-MRW, anatomical causes of mismatches between RNFL and BMO-MRW.

RESULTS

Mismatch analysis revealed true mismatches between RNFL and BMO-MRW in 7.7% of sectors. High BMO-MRW with low corresponding RNFL mismatches were most frequently located at the 45° and 322.5° sectors, whereas high RNFL with corresponding low BMO-MRW mismatches peaked at the 75° sector. Large blood vessels accounted for 90.9% of high RNFL with low BMO-MRW mismatches. Small to large blood vessels accounted for 62.9% of high BMO-MRW with low RNFL mismatches; the remaining mismatches could be attributed to retinoschisis or inclusion of outer retinal layers in BMO-MRW measurements.

CONCLUSIONS

Although overall agreement between RNFL and BMO-MRW measurements is good in areas with advanced damage, blood vessels and other anatomical factors can cause discrepancies between the 2 types of structural measurements and need to be considered when evaluating the utility of such measurements for detection of change.

FINANCIAL DISCLOSURES

Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

摘要

目的

比较青光眼患者视乳头周围视网膜神经纤维层(RNFL)厚度与布鲁赫膜开口最小边缘宽度(BMO-MRW)厚度之间的差异。

设计

横断面观察性研究。

研究对象

186只青光眼患眼(118例患者)。

方法

导出参加高级青光眼进展研究的患者在最后一次可获得随访时的OCT视神经乳头容积扫描图像。将RNFL和BMO-MRW测量值平均到相应的7.5°扇形区域,并将鼻侧扇形区域数据排除在分析之外。采用两阶段筛选过程来识别RNFL和BMO-MRW测量值之间的真正不匹配情况,即RNFL或BMO-MRW值在颞上-鼻-颞下-颞曲线中处于低于第1百分位数范围,而其对应值处于高于第1百分位数范围。绘制这些不匹配情况的患病率,并审查相应图像以确定这些差异的潜在原因。

主要观察指标

RNFL与BMO-MRW之间不匹配的比例、RNFL与BMO-MRW之间不匹配的位置、RNFL与BMO-MRW之间不匹配的解剖学原因。

结果

不匹配分析显示,7.7%的扇形区域中RNFL与BMO-MRW之间存在真正的不匹配。BMO-MRW高而相应RNFL低的不匹配最常位于45°和322.5°扇形区域,而RNFL高而相应BMO-MRW低的不匹配在75°扇形区域达到峰值。大血管占RNFL高而BMO-MRW低的不匹配情况的90.9%。小至大血管占BMO-MRW高而RNFL低的不匹配情况的62.9%;其余不匹配情况可归因于视网膜劈裂或BMO-MRW测量中包含外层视网膜。

结论

尽管在损伤严重的区域RNFL和BMO-MRW测量值总体一致性良好,但血管和其他解剖学因素可导致这两种结构测量值之间存在差异,在评估此类测量用于检测变化的效用时需要予以考虑。

财务披露

本文末尾的脚注和披露中可能会发现专有或商业披露信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/df3e/11474368/f74e4f2ca8b0/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验