Suppr超能文献

抗 HTLV-1 抗体定量检测在 HTLV-1 相关脊髓病中的诊断价值。

Diagnostic Value of Anti-HTLV-1-Antibody Quantification in Cerebrospinal Fluid for HTLV-1-Associated Myelopathy.

机构信息

Department of Rare Diseases Research, Institute of Medical Science, St. Marianna University School of Medicine, Kawasaki 216-8512, Japan.

Department of Neurology, St. Marianna University School of Medicine, Kawasaki 216-8511, Japan.

出版信息

Viruses. 2024 Oct 8;16(10):1581. doi: 10.3390/v16101581.

Abstract

The diagnostic accuracy of cerebrospinal fluid (CSF) anti-human T-cell leukemia virus type I (HTLV-1) antibody testing for HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM) remains unclear. Therefore, we measured the anti-HTLV-1 antibody levels in CSF using various test kits, evaluated the stability of CSF antibodies, and performed a correlation analysis using the particle agglutination (PA) method, as well as a receiver operating characteristic (ROC) analysis between patients with HAM and carriers. The CSF anti-HTLV-1 antibody levels were influenced by freeze-thaw cycles but remained stable when the CSF was refrigerated at 4 °C for up to 48 h. Measurements from 92 patients (69 patients with HAM and 23 carriers) demonstrated a strong correlation (r > 0.9) with the PA method across all six quantifiable test kits. All six test kits, along with CSF neopterin and CXCL10, exhibited areas under the ROC curve greater than 0.9, indicating a high diagnostic performance for HAM. Among these, five test kits, Lumipulse and Lumipulse Presto HTLV-I/II, HISCL-UD (a kit under development), HTLV-Abbott, and Elecsys HTLV-I/II, established a cutoff with 100% sensitivity and maximum specificity, achieving a sensitivity of 100% and a specificity ranging from 43.5% to 56.5%. This cutoff value, in combination with clinical findings, will aid in the accurate diagnosis of HAM.

摘要

脑脊液(CSF)抗人类 T 细胞白血病病毒 1 型(HTLV-1)抗体检测对 HTLV-1 相关脊髓病/热带痉挛性截瘫(HAM)的诊断准确性仍不清楚。因此,我们使用各种试剂盒测量 CSF 中的抗 HTLV-1 抗体水平,评估 CSF 抗体的稳定性,并使用颗粒凝集(PA)法和受试者工作特征(ROC)分析进行相关性分析,以比较 HAM 患者和携带者之间的关系。CSF 抗 HTLV-1 抗体水平受冻融循环影响,但在 4°C 冷藏时最多可稳定 48 小时。来自 92 名患者(69 名 HAM 患者和 23 名携带者)的测量值与 PA 方法在所有六个可量化的试剂盒中均显示出强烈的相关性(r>0.9)。所有六个试剂盒,以及 CSF 中新蝶呤和 CXCL10,在 ROC 曲线下面积均大于 0.9,表明对 HAM 具有较高的诊断性能。其中,五个试剂盒,Lumipulse 和 Lumipulse Presto HTLV-I/II、HISCL-UD(一种正在开发的试剂盒)、HTLV-Abbott 和 Elecsys HTLV-I/II,确定了 100%敏感性和最大特异性的截断值,达到 100%的敏感性和 43.5%至 56.5%的特异性范围。该截断值结合临床发现将有助于 HAM 的准确诊断。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6a2a/11512244/69b570030bdc/viruses-16-01581-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验