Determination of the Normative Value of Fetal Left Brachiocephalic Vein Diameter Using Ultrasound in a Tertiary Care Hospital in Eastern India.

作者信息

Maitra Debabrata, Hela Suman, De Saumyen, Mandal Sandip K, Bhowmick Tanmoy, Mandal Sanghamitra, Sutradhar Mrinmoy, Sarkar Ayan

机构信息

Radiodiagnosis, College of Medicine and Sagore Dutta Hospital, Kolkata, IND.

Paediatrics, College of Medicine and Sagore Dutta Hospital, Kolkata, IND.

出版信息

Cureus. 2024 Sep 26;16(9):e70258. doi: 10.7759/cureus.70258. eCollection 2024 Sep.

Abstract

INTRODUCTION

Fetal ultrasound plays a vital role in prenatal care by offering key insights into fetal growth and facilitating the early identification of congenital abnormalities. Among various anatomical structures, the fetal left brachiocephalic vein (FLBCV) plays a significant role in fetal circulation, yet normative data for FLBCV dimensions are limited, particularly in diverse populations. This study aims to establish normative values for FLBCV diameter in fetuses between 18 and 23 weeks of gestation in a tertiary care hospital in Eastern India. Such data are essential for accurate clinical assessment and early diagnosis of potential congenital anomalies.

METHODOLOGY

This descriptive study was conducted at the College of Medicine and Sagore Dutta Hospital, Kolkata, India, from January to December 2022. The study included 287 singleton pregnancies between 18 and 23 weeks of gestation, excluding cases with maternal or fetal conditions that could affect the measurements. LBCV diameter was measured using transabdominal ultrasound, and the normative values were established using percentile charts. Correlation analyses were performed to assess the relationship between FLBCV diameter and various fetal and maternal parameters. Linear regression analysis was done to identify significant predictors of FLBCV diameter.

RESULTS

FLBCV diameter showed a consistent increase with gestational age, ranging from a median of 1.87 mm at 18 completed weeks to 2.27 mm at 22 completed weeks. The 95th percentile values exhibited more pronounced growth, particularly between 18 and 20 weeks. Significant positive correlations were observed between FLBCV diameter and fetal biometric parameters such as biparietal diameter, head circumference, abdominal circumference, and femur length. Head circumference emerged as the most significant predictor (p=0.007) of FLBCV diameter in the linear regression model.

CONCLUSION

This study provides essential normative data on FLBCV diameter for the Indian population, offering a valuable reference for clinicians in prenatal diagnostics. The incorporation of FLBCV measurement in basic fetal echocardiography, which is a part of the second-trimester fetal anomaly scan, could enhance the detection of congenital anomalies, contributing to improved prenatal care.

摘要

引言

胎儿超声检查在产前护理中起着至关重要的作用,它能提供有关胎儿生长的关键见解,并有助于早期发现先天性异常。在各种解剖结构中,胎儿左头臂静脉(FLBCV)在胎儿循环中起着重要作用,但关于FLBCV尺寸的规范数据有限,尤其是在不同人群中。本研究旨在确定印度东部一家三级护理医院中妊娠18至23周胎儿的FLBCV直径的规范值。这些数据对于准确的临床评估和潜在先天性异常的早期诊断至关重要。

方法

本描述性研究于2022年1月至12月在印度加尔各答的医学院和萨戈尔·杜塔医院进行。该研究纳入了287例妊娠18至23周的单胎妊娠,排除了可能影响测量结果的母体或胎儿情况。使用经腹超声测量LBCV直径,并使用百分位数图表确定规范值。进行相关性分析以评估FLBCV直径与各种胎儿和母体参数之间的关系。进行线性回归分析以确定FLBCV直径的重要预测因素。

结果

FLBCV直径随孕周持续增加,从妊娠18周时的中位数1.87毫米到妊娠22周时的2.27毫米。第95百分位数的值增长更为明显,尤其是在18至20周之间。FLBCV直径与胎儿生物测量参数如双顶径、头围、腹围和股骨长度之间存在显著正相关。在线性回归模型中,头围成为FLBCV直径的最显著预测因素(p = 0.007)。

结论

本研究为印度人群提供了关于FLBCV直径的重要规范数据,为临床医生进行产前诊断提供了有价值的参考。将FLBCV测量纳入基本胎儿超声心动图(这是孕中期胎儿畸形扫描的一部分)可以提高先天性异常的检测率,有助于改善产前护理。