The association of hypoxemia and cardiac arrhythmias with fiberoptic bronchoscopy (FOB) is known. The effects of various methods of inserting the bronchoscope on blood oxygen tensions, the true prevalence of arrhythmias, and the clinical significance of PaO2 and rhythm changes are poorly defined. Arterial blood gas values, oxygen saturation and cardiac arrhythmias detected by 24-hour Holter monitoring were compared in 20 male patients undergoing either transoral or transnasal FOB. No significant difference in oxygen saturation was found; however, PaO2 values fluctuated widely and unpredictably and were significantly higher in the eight patients in the transnasal FOB group. No life-threatening arrhythmias were induced during bronchoscopy; however, because of minor arrhythmias such as sinus tachycardia, the overall frequency of arrhythmias rose from 60% to 65%. The incidence of arrhythmias in this study was similar to that reported during pulmonary function testing.

摘要

低氧血症和心律失常与纤维支气管镜检查(FOB)之间的关联是已知的。各种插入支气管镜方法对血氧张力的影响、心律失常的真实发生率以及动脉血氧分压(PaO2)和节律变化的临床意义尚不明确。对20名接受经口或经鼻纤维支气管镜检查的男性患者的动脉血气值、血氧饱和度以及通过24小时动态心电图监测检测到的心律失常进行了比较。未发现血氧饱和度有显著差异;然而,PaO2值波动广泛且不可预测,经鼻纤维支气管镜检查组的8名患者的PaO2值显著更高。支气管镜检查期间未诱发危及生命的心律失常;然而,由于窦性心动过速等轻微心律失常,心律失常的总体发生率从60%升至65%。本研究中心律失常的发生率与肺功能测试期间报告的发生率相似。