Suppr超能文献

L测试在多发性硬化症患者中的信度和效度

Reliability and Validity of the L Test in Persons With Multiple Sclerosis.

作者信息

Bilek Furkan, Demir Caner F

机构信息

Department of Gerontology, Fethiye Faculty of Health Sciences, Muğla Sıtkı Koçman University, Muğla, Türkiye.

Department of Neurology, Faculty of Medical, Fırat University, Elazığ, Türkiye.

出版信息

Percept Mot Skills. 2025 Apr;132(2):262-277. doi: 10.1177/00315125241298728. Epub 2024 Nov 7.

Abstract

The L Test has been developed to assess balance and gait disorders. Our aim in this study was to estimate the test-retest reliability and validity of the L Test when used with 82 persons with multiple sclerosis (PwMS). For these participants, we examined the degree of agreement between the results of a first and second administration of the L Test (separated by one day), using Bland-Altman analysis and intra-class correlation coefficients (ICCs). We computed minimal detectable change (MDC) and standard error of measurement (SEM) values for the L Test and evaluated concurrent validity by correlating L Test results with the Timed Up and Go test (TUG) and the 10-minute Walk Test (10MWT). Prior to administering these measurements, we randomized the sequence of the test administrations to our participants. The Bland-Altman analysis showed that L Test was reproducible, with upper and lower limits of agreement of 0.99 and -1.45 seconds, respectively. The L Test demonstrated excellent test-retest reliability, with an ICC value of 0.996 (95% CI: 0.994-0.998). Cronbach's alpha coefficient was 0.996. The performance of the L Test is measured by seconds required to complete the task, and we found the L Test SEM value to be 0.35 seconds, and its MDC value to be 0.97 seconds. The L Test showed a strong correlation with both the TUG test (rho = 0.936; < .001) and the 10MWT (rho = 0.925; < .001). We concluded that the L Test is a reliable and valid \ tool for assessing functional mobility and balance in PwMS.

摘要

L测试已被开发用于评估平衡和步态障碍。我们在本研究中的目的是评估L测试在82名多发性硬化症患者(PwMS)中使用时的重测信度和效度。对于这些参与者,我们使用Bland-Altman分析和组内相关系数(ICC)来检查L测试首次和第二次施测(间隔一天)结果之间的一致程度。我们计算了L测试的最小可检测变化(MDC)和测量标准误差(SEM)值,并通过将L测试结果与定时起立行走测试(TUG)和10分钟步行测试(10MWT)相关来评估同时效度。在进行这些测量之前,我们将测试施测顺序随机分配给参与者。Bland-Altman分析表明L测试具有可重复性,一致性上限和下限分别为0.99秒和-1.45秒。L测试显示出出色的重测信度,ICC值为0.996(95%CI:0.994-0.998)。Cronbach's alpha系数为0.996。L测试的表现通过完成任务所需的秒数来衡量,我们发现L测试的SEM值为0.35秒,其MDC值为0.97秒。L测试与TUG测试(rho = 0.936;<0.001)和10MWT(rho = 0.925;<0.001)均显示出强相关性。我们得出结论,L测试是评估PwMS患者功能移动性和平衡的可靠且有效的工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7d98/11894887/6aee1b278c09/10.1177_00315125241298728-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验