Suppr超能文献

VisuMax与VISUMAX 800用于复合性近视散光的角膜屈光透镜切除术的视觉和屈光结果比较

Comparison of Visual and Refractive Outcomes of Keratorefractive Lenticule Extraction for Compound Myopic Astigmatism Between VisuMax and VISUMAX 800.

作者信息

Varman Aadithreya, Varman Arulmozhi, Balakumar Dinesh

机构信息

Uma Eye Clinic, Chennai, India.

出版信息

Clin Ophthalmol. 2024 Nov 30;18:3557-3566. doi: 10.2147/OPTH.S492552. eCollection 2024.

Abstract

PURPOSE

To evaluate the visual outcomes of keratorefractive lenticule extraction using a new version of a femtosecond laser platform with semi-automated cyclotorsion compensation in comparison to the previous generation without cyclotorsion control.

METHODS

This was an ambispective study of consecutive eyes treated by SMILE with the VisuMax and VISUMAX 800 femtosecond lasers at the Uma Eye clinic, Chennai, India between June 2022 and July 2023. Inclusion criteria were myopia up to -10 D and astigmatism between 1.5 D and 5 D. Data was retrospectively collected from patients that underwent SMILE using the VisuMax without cyclotorsion compensation and prospectively collected from patients undergoing SMILE using the VISUMAX 800 with Oculign and Centralign software aids.

RESULTS

Data was collected from a total of 220 eyes that underwent routine SMILE; 115 eyes with VisuMax (VM500 group) and 105 eyes with VISUMAX 800 (VM800 group). The mean attempted spherical equivalent was -4.82±2.16 D in the VM500 group and -4.80±2.24 in the VM800 group. At the 3-month postoperative visit, 94% of eyes in the VM500 group and 98% of eyes in the VM800 group had an UDVA of 20/20 or better. Accuracy of the SEQ showed that 71% of eyes were within ±0.50 D and 100% were within ±1.00 D of target in the VM500 group and 96% of eyes were within ±0.50 D and 100% were within ±1.00 D of target in the VM800 group. There were no reported cases of suction loss or any other intraoperative complication in either group.

CONCLUSION

SMILE with the VisuMax and VISUMAX 800 provided excellent visual and refractive outcomes for subjects with myopic astigmatism. The VISUMAX 800, using Oculign and Centralign aids, demonstrated better accuracy when correcting cylinder greater than 2 D compared to the VisuMax without using manual cyclotorsion compensation.

摘要

目的

与上一代无旋转控制的飞秒激光平台相比,评估使用具有半自动旋转补偿功能的新一代飞秒激光平台进行角膜屈光透镜切除术的视觉效果。

方法

这是一项在印度钦奈乌玛眼科诊所对2022年6月至2023年7月期间接受VisuMax和VISUMAX 800飞秒激光小切口基质透镜切除术(SMILE)治疗的连续病例进行的前瞻性和回顾性研究。纳入标准为近视度数最高达-10 D且散光度数在1.5 D至5 D之间。回顾性收集使用无旋转补偿的VisuMax进行SMILE手术的患者数据,并前瞻性收集使用配备Oculign和Centralign软件辅助装置的VISUMAX 800进行SMILE手术的患者数据。

结果

共收集了220只接受常规SMILE手术眼睛的数据;其中115只眼睛使用VisuMax(VM500组),105只眼睛使用VISUMAX 800(VM800组)。VM500组平均预期等效球镜度数为-4.82±2.16 D,VM800组为-4.80±2.24 D。术后3个月随访时,VM500组94%的眼睛和VM800组98%的眼睛最佳矫正视力(UDVA)达到20/20或更好。等效球镜度数(SEQ)的准确性显示,VM500组71%的眼睛在目标值±0.50 D范围内,100%在目标值±1.00 D范围内;VM800组96%的眼睛在目标值±0.50 D范围内,100%在目标值±1.00 D范围内。两组均未报告出现负压损失或任何其他术中并发症的病例。

结论

使用VisuMax和VISUMAX 800进行SMILE手术为近视散光患者提供了出色的视觉和屈光效果。与未使用手动旋转补偿的VisuMax相比,配备Oculign和Centralign辅助装置的VISUMAX 800在矫正大于2 D的散光时显示出更高的准确性。