Suppr超能文献

850纳米发光二极管照射对下颌拥挤前牙排齐的影响:一项随机对照临床试验

Effect of 850 nm LED irradiation on the alignment of crowded mandibular anterior teeth: a randomized controlled clinical trial.

作者信息

Farhadian Nasrin, Miresmaeili Amirfarhang, Farhadifard Homa, Banisafar Ziba, Farhadian Maryam, Beiglar Vahid, Ahmadpour Yousef

机构信息

Department of Orthodontics, School of Dentistry, Hamadan Dental Research Centre, Hamadan University of Medical Sciences, Hamadan, 65417838741, Iran.

Department of Orthodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, 65417838741, Iran.

出版信息

Clin Oral Investig. 2024 Dec 26;29(1):30. doi: 10.1007/s00784-024-06044-z.

Abstract

INTRODUCTION

This study aims to determine if intraoral 850 nm LED irradiation could reduce the duration of lower anterior crowding alignment.

METHODS

In a parallel-designed, randomized controlled clinical trial 60 patients with 2 to 6 mm of lower incisor crowding who need non-extraction treatment, were randomly assigned to the intervention and control groups by block randomization (36 females, 24 males, mean age: 19.93 ± 3.05). MBT brackets (0.022 × 0.28-inch) were bonded for both groups and the NiTi wires in sequences were put in place until correction of crowding. The intra-oral LED device with a wavelength of 850 nm and power density of 70 mW/cm was used for 5 min per day in the intervention group. The control group did not receive any light. The primary outcome was the duration of crowding correction. The patient's pain according the modified McGill pain questionnaire was the secondary outcome. The Cox regression model was used to compare groups. Mann-Whitney test was used for pain analysis.

RESULTS

The crowding at baseline was the same between the two groups (P > 0.05). Duration of treatment in the intervention group was 104.7 days (95% CI: 95.6 -113.8) and significantly shorter than 161.9 days (95% CI: 151.5 -171.2) in the control group. The control group experienced a significantly higher pain score of 6.8 (95% CI: 6.1-7.5) immediately after archwire placement than the intervention group 5.4 (95% CI: 4.6-6.3).

CONCLUSIONS

Intra-oral LED 850 nm significantly decreased the relieving time of lower incisor crowding by up to 36% and reduced pain experience.

摘要

引言

本研究旨在确定口腔内850纳米发光二极管(LED)照射是否能缩短下前牙排齐所需时间。

方法

在一项平行设计的随机对照临床试验中,将60例下切牙拥挤2至6毫米且需要非拔牙治疗的患者,通过区组随机化分为干预组和对照组(女性36例,男性24例,平均年龄:19.93±3.05岁)。两组均粘结MBT托槽(0.022×0.28英寸),并依次置入镍钛丝直至排齐拥挤。干预组每天使用波长850纳米、功率密度70毫瓦/平方厘米的口腔内LED装置照射5分钟。对照组未接受任何光照。主要观察指标为拥挤矫正时间。根据改良麦吉尔疼痛问卷评估患者疼痛程度作为次要观察指标。采用Cox回归模型比较组间差异。采用曼-惠特尼检验进行疼痛分析。

结果

两组基线时的拥挤程度相同(P>0.05)。干预组的治疗时间为104.7天(95%置信区间:95.6 - 113.8),显著短于对照组的161.9天(95%置信区间:151.5 - 171.2)。在弓丝置入后,对照组的疼痛评分显著高于干预组,分别为6.8(95%置信区间:6.1 - 7.5)和5.4(95%置信区间:4.6 - 6.3)。

结论

口腔内850纳米LED照射可使下切牙拥挤缓解时间显著缩短多达36%,并减轻疼痛感受。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验