Abstract

The current study investigates and compares the biological effects of ultrathin conformal coatings of zirconium dioxide (ZrO) and vanadium pentoxide (VO) on osteoblastic MG-63 cells grown on TiO nanotube layers (TNTs). Coatings were achieved by the atomic layer deposition (ALD) technique. TNTs with average tube diameters of 15, 30, and 100 nm were fabricated on Ti substrates (via electrochemical anodization) and were used as primary substrates for the study. The MG-63 cell growth and proliferation after 48 h of incubation on hybrid TNTs/ZrO and TNTs/VO surfaces was evaluated in comparison to the uncoated TNTs of each diameter. The density of viable MG-63 cells was assessed for all the TNT surfaces, along with the cell morphology and the spreading behavior (i.e., the cell length). The ultrathin coatings retained the original morphology of the TNTs but changed the surface chemical composition, wettability, and cell behavior, whose interplay is the subject of the present investigation. These findings offer interesting views on the influence of the composition of biomedical implant surfaces, triggered by ALD ultrathin coatings on them. The outcomes of this work shed light on the assessment of the biocompatibility of the two different ALD coatings.

摘要

本研究调查并比较了二氧化锆(ZrO)和五氧化二钒(VO)超薄 conformal 涂层对生长在 TiO 纳米管层(TNTs)上的成骨细胞 MG-63 的生物学效应。涂层通过原子层沉积(ALD)技术制备。在 Ti 基底上(通过电化学阳极氧化)制备了平均管径为 15、30 和 100 nm 的 TNTs,并将其用作本研究的主要基底。与每种直径的未涂层 TNTs 相比,评估了 MG-63 细胞在 TNTs/ZrO 和 TNTs/VO 混合表面上孵育 48 小时后的生长和增殖情况。评估了所有 TNT 表面上存活的 MG-63 细胞的密度,以及细胞形态和铺展行为(即细胞长度)。超薄涂层保留了 TNTs 的原始形态,但改变了表面化学成分、润湿性和细胞行为,它们之间的相互作用是本研究的主题。这些发现为 ALD 超薄涂层引发的生物医学植入物表面成分的影响提供了有趣的观点。这项工作的结果为评估两种不同的 ALD 涂层的生物相容性提供了启示。