Nakagawa Haruka, Katoh Munenori, Arai Saori, Hirano Masahiro, Hiiragi Yukinobu
Department of Physical Therapy, International University of Health and Welfare: Minato-ku, Tokyo 107-0062, Japan.
Department of Physical Therapy, Faculty of Health Science, SBC Tokyo Medical, Japan.
J Phys Ther Sci. 2025 Jan;37(1):57-61. doi: 10.1589/jpts.37.57. Epub 2025 Jan 1.
[Purpose] This study aimed to investigate the reliability and validity of measuring isometric ankle plantar flexion strength using a handheld dynamometer (HHD) with a belt and metal plate. [Participants and Methods] This study enrolled 35 young healthy participants (22 men and 13 women, mean age; 21.2 years). To evaluate reliability, two examiners measured ankle plantar flexor strength twice for all participants using an HHD. To evaluate validity, an examiner measured ankle plantar flexor strength twice in men using an isokinetic dynamometer (IKD). [Results] Intra-rater reliability was almost perfect for examiners A and B, whereas their interrater reliability was substantial. Pearson's correlation coefficients for the HHD and IKD in men were not significantly correlated. [Conclusion] The intra- and interrater reliabilities of HHD measurements, as evaluated by the data for all participants, were high. However, the validity of HHD measurements evaluated by men was low if IKD-measured values were used as a reference.
[目的] 本研究旨在探讨使用带有束带和金属板的手持测力计(HHD)测量等长踝关节跖屈力量的可靠性和有效性。[参与者与方法] 本研究招募了35名年轻健康参与者(22名男性和13名女性,平均年龄21.2岁)。为评估可靠性,两名检查者使用HHD对所有参与者的踝关节跖屈肌力量进行了两次测量。为评估有效性,一名检查者使用等速测力计(IKD)对男性的踝关节跖屈肌力量进行了两次测量。[结果] 检查者A和B的组内信度几乎完美,而他们的组间信度较高。男性中HHD和IKD的皮尔逊相关系数无显著相关性。[结论] 根据所有参与者的数据评估,HHD测量的组内和组间信度较高。然而,如果以IKD测量值作为参考,男性中评估的HHD测量有效性较低。