J Phys Ther Sci. 2022 Jun;34(6):463-466. doi: 10.1589/jpts.34.463. Epub 2022 Jun 6.
[Purpose] This study aimed to investigate the test-retest reliability of isometric ankle plantar flexion strength measurements performed by a hand-held dynamometer (HHD) using two belts and a newly devised fixation plate. [Participants and Methods] The participants were 83 healthy individuals (female, n=31; male, n=52) with an average age of 20 years. An HHD (μTas F-1) sensor was fixed using two belts and a newly developed metal device to the measurement site on the dominant foot of a participant who was in a sitting position. Measurements were performed twice for each participant. [Results] The average value was 65.6 kgf (bodyweight ratio, 127.3%) for female and 88.0 kgf (136.9%) for male participants. The intraclass correlation coefficients of the two measurements were 0.915 for female and 0.938 for male participants. The minimum detectable change at 95% was 10.1 kgf (12.1% of the average value) for female and 12.1 kgf (15.4%) for male participants. [Conclusion] The test-retest reliability of measuring the ankle plantar flexion strength performed by an HHD using a belt and plate is high. Therefore, the increase or decrease in muscle strength should be judged based on the minimal detectable change with 95% confidence.
[目的] 本研究旨在探讨使用两条带子和新设计的固定板的手持式测力计(HHD)测量等长踝关节跖屈力量的重测信度。[参与者与方法] 参与者为83名健康个体(女性31名,男性52名),平均年龄20岁。将HHD(μTas F-1)传感器使用两条带子和新开发的金属装置固定在坐位参与者优势脚的测量部位。对每位参与者进行两次测量。[结果] 女性参与者的平均值为65.6千克力(体重比127.3%),男性参与者为88.0千克力(136.9%)。两次测量的组内相关系数女性为0.915,男性为0.938。95%时的最小可检测变化女性为10.1千克力(平均值的12.1%),男性为12.1千克力(15.4%)。[结论] 使用带子和固定板的HHD测量踝关节跖屈力量的重测信度很高。因此,应根据95%置信度下的最小可检测变化来判断肌肉力量的增加或减少。