Suppr超能文献

用于定量马胰岛素的自动荧光酶免疫测定法的评估及其与其他五种免疫测定法的比较。

Evaluation of an Automated Fluorescence Enzyme Immunoassay for Quantification of Equine Insulin and Comparison to Five Other Immunoassays.

作者信息

Nolen-Walston Rose D, Kulp Jeaneen C, Stefanovski Darko, van Eps Andrew W

机构信息

Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, Pennsylvania, USA.

出版信息

J Vet Intern Med. 2025 Mar-Apr;39(2):e70038. doi: 10.1111/jvim.70038.

Abstract

BACKGROUND

Hyperinsulinemia is an important and treatable risk factor for laminitis in horses.

OBJECTIVES

Evaluate the Tosoh AIA-360 automated fluorescence enzyme immunoassay for the measurement of serum insulin concentrations in horses, and compare it to five other immunoassays for insulin quantification.

ANIMALS

One hundred serum samples from 83 horses were submitted for insulin measurement.

METHODS

The Tosoh AIA-360 was assessed against a reference assay (radioactive immunoassay; RIA). Using the same samples, TOS-FEIA, ELISA, and three chemiluminescent immunoassays (CLIA) were assessed for correlation and agreement with RIA.

RESULTS

The TOS-FEIA showed excellent correlation with RIA (r = 0.94, p < 0.0001) and good agreement, with a Bland-Altman constant bias (limits of agreement) of -23.8 μIU/mL (-74.6 to 27.0) and Passing-Bablok fit of y = -8.9 + 0.78x. Mean coefficients of variation were 1.8% for intra-assay and 5.7% for inter-assay precision, with mean recovery upon dilution of 104.2%. The assay comparison yielded good or excellent agreement (constant bias, limits of agreement) with RIA in the < 100 μIU/mL cohort for the ELISA (-7.0, -21.4 to 7.4) and the Cobas e CLIA (-31.4, -60.9 to -1.6). Spuriously high results (2 to > 10-fold of RIA result) were obtained in approximately 10% of results from both Immulite 2000 and 2000XPi CLIA analyzers, rendering the agreement poor.

CONCLUSIONS AND CLINICAL IMPORTANCE

The TOS-FEIA had acceptable accuracy and precision for clinical use, including at concentrations of insulin < 100 μIU/mL. The ELISA and one CLIA (Cobas e) showed acceptable accuracy, but the Cobas e demonstrated marked bias compared with RIA. Both Immulite CLIA assays exhibited unacceptable accuracy.

摘要

背景

高胰岛素血症是马匹患蹄叶炎的一个重要且可治疗的风险因素。

目的

评估东芝AIA - 360自动荧光酶免疫分析法用于测定马匹血清胰岛素浓度的情况,并将其与其他五种胰岛素定量免疫分析法进行比较。

动物

提交了来自83匹马的100份血清样本用于胰岛素测定。

方法

将东芝AIA - 360与参考分析法(放射免疫分析法;RIA)进行评估比较。使用相同样本,对TOS - FEIA、酶联免疫吸附测定(ELISA)和三种化学发光免疫分析法(CLIA)与RIA的相关性和一致性进行评估。

结果

TOS - FEIA与RIA显示出极好的相关性(r = 0.94,p < 0.0001)和良好的一致性,Bland - Altman恒定偏差(一致性界限)为 - 23.8 μIU/mL(-74.6至27.0),Passing - Bablok拟合为y = -8.9 + 0.78x。批内变异系数均值为1.8%,批间精密度变异系数均值为5.7%,稀释后的平均回收率为104.2%。在< 100 μIU/mL队列中,ELISA(-7.0,-21.4至7.4)和Cobas e CLIA(-31.4,-60.9至-1.6)与RIA的分析比较显示出良好或极好的一致性(恒定偏差,一致性界限)。在Immulite 2000和2000XPi CLIA分析仪的约10%的结果中获得了虚假的高结果(RIA结果的2至> 10倍),导致一致性较差。

结论及临床意义

TOS - FEIA在临床应用中具有可接受的准确性和精密度,包括在胰岛素浓度< 100 μIU/mL时。ELISA和一种CLIA(Cobas e)显示出可接受的准确性,但Cobas e与RIA相比表现出明显偏差。两种Immulite CLIA分析方法均表现出不可接受的准确性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3ea1/11884604/4ad535fc1b26/JVIM-39-e70038-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验