Suppr超能文献

用脱气次氯酸钠溶解牛腭组织。

Dissolution of Bovine Palatal Tissue with Degassed Sodium Hypochlorite.

作者信息

Fang Justin, Shen Zhen, van der Hoeven Ransome, Jaramillo David E

机构信息

Department of Endodontics, School of Dentistry, University of Texas Health Science Center at Houston, Houston, TX 77054, USA.

出版信息

Dent J (Basel). 2025 Feb 28;13(3):110. doi: 10.3390/dj13030110.

Abstract

To investigate the tissue dissolution efficacy of different concentrations of sodium hypochlorite (NaOCl) using the GentleWave technology (GW) and compare it with that of passive ultrasonic irrigation. This study will provide a novel in vitro model used to evaluate the tissue dissolution efficacy of different concentrations of NaOCl using the GentleWave procedure. Palatal bovine tissue was standardized by weight at 70-75 mg (average of 74.4 mg). The samples were divided into three groups of = 10, Group 1: GW + 0.5% NaOCl, Group 2: GW + 3% NaOCl, and Group 3: ultrasonic group (US) + 6% NaOCl, and a control group of = 2 with GW + HO. A specialized CleanFlow instrument was manufactured for the GW groups. For the US group, an apparatus was developed to allow the tissue to be in close contact with a freely operating ultrasonic tip. Each group was operated with its specific irrigants and dissolution times were obtained unless the samples were not visually dissolved within 5 min, and the dissolution rates were calculated. Dissolution times and rates were analyzed using univariate analysis of variance followed by a -test. The GW groups with 0.5% and 3% NaOCl dissolved entire tissue samples within 5 min and had average dissolution times of 227.5 s (Group 1) and 81.5 s (Group 2). GW with water had a higher tissue dissolution rate than ultrasonics with 6% NaOCl. The GentleWave using a lower concentration of NaOCl showed a similar clinical efficacy of dissolving tissues but displayed a significantly faster rate when compared with passive ultrasonic agitation.

摘要

使用GentleWave技术(GW)研究不同浓度次氯酸钠(NaOCl)的组织溶解效果,并将其与被动超声冲洗的效果进行比较。本研究将提供一种新型体外模型,用于评估使用GentleWave程序时不同浓度NaOCl的组织溶解效果。将腭部牛组织按重量标准化为70 - 75毫克(平均74.4毫克)。样本分为三组,每组n = 10,第1组:GW + 0.5% NaOCl,第2组:GW + 3% NaOCl,第3组:超声组(US)+ 6% NaOCl,以及对照组n = 2,为GW + HO。为GW组制造了专门的CleanFlow仪器。对于US组,开发了一种装置,使组织能够与自由操作的超声探头紧密接触。每组使用其特定的冲洗剂进行操作,记录溶解时间,除非样本在5分钟内未在视觉上溶解,然后计算溶解速率。使用单因素方差分析和t检验分析溶解时间和速率。含0.5%和3% NaOCl的GW组在5分钟内溶解了所有组织样本,平均溶解时间分别为227.5秒(第1组)和81.5秒(第2组)。用水的GW组比用6% NaOCl的超声组具有更高的组织溶解率。使用较低浓度NaOCl的GentleWave显示出类似的组织溶解临床效果,但与被动超声搅拌相比,溶解速度明显更快。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验