Hamamoto Shuzo, Chaya Ryosuke, Taguchi Kazumi, Inoue Takaaki, Okada Shinsuke, Boonyapalanant Chatporn, Isogai Masahiko, Kawase Kengo, Torii Koei, Unno Rei, Okada Atsushi, Yasui Takahiro
Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan.
SMART Study Group, Tokyo, Japan.
Sci Rep. 2025 Mar 27;15(1):10614. doi: 10.1038/s41598-025-95095-7.
This study evaluated the adherence of bacteria, calcium, and magnesium to three different ureteral stents after endoscopic surgery for urinary calculi. We randomly assigned 61 patients requiring the insertion of ureteral stents after urinary calculi treatment into three groups: Percuflex with a coating composition of Hydroplus (n = 21); Tria with a coating composition of Percushied (n = 22); and InLay Optima, which had a proprietary pHreeCoat coating (n = 18). All stents were removed and evaluated 1 month after treatment. The primary outcome was biomineral attachment to the ureteral stent. Calcium and magnesium contents were measured using atomic absorption spectrometry after the stent had been vortexed in a solution of saline and hydrochloric acid at pH 2. Bacteria were measured through flow cytometry of the washing solution collected by decantation after stent fragments had been immersed and vortexed in a saline solution. Median amounts of calcium and magnesium adhered to Percuflex were significantly higher than those adhered to Tria and InLay Optima. The median number of bacteria adhered was also highest in Percuflex compared to that in the other two groups, although without a statistically significant difference. These findings suggest that selecting stents with superior coating materials enhances patient outcomes and reduces stent-related complications.
本研究评估了在尿路结石内镜手术后,细菌、钙和镁在三种不同输尿管支架上的附着情况。我们将61例尿路结石治疗后需要插入输尿管支架的患者随机分为三组:涂层成分是Hydroplus的Percuflex(n = 21);涂层成分是Percushied的Tria(n = 22);以及具有专利pHreeCoat涂层的InLay Optima(n = 18)。所有支架在治疗1个月后取出并进行评估。主要结局是生物矿物质在输尿管支架上的附着情况。在支架于pH值为2的盐水和盐酸溶液中涡旋后,使用原子吸收光谱法测量钙和镁的含量。在支架碎片浸入盐水溶液并涡旋后,通过对倾析收集的洗涤液进行流式细胞术测量细菌数量。附着在Percuflex上的钙和镁的中位数含量显著高于附着在Tria和InLay Optima上的含量。与其他两组相比,附着在Percuflex上的细菌中位数数量也是最高的,尽管没有统计学上的显著差异。这些发现表明,选择具有优质涂层材料的支架可改善患者预后并减少与支架相关的并发症。