使用自动血压监测仪对急诊医疗服务(EMT)现场、转运途中及急诊科的血压测量结果进行比较。

Comparison of EMT blood pressure measurements with an automated blood pressure monitor: on scene, during transport, and in the emergency department.

作者信息

Hunt R C, Allison E J, Whitley T W, Robinson M J, Smart T L

出版信息

Ann Emerg Med. 1985 Sep;14(9):871-5. doi: 10.1016/s0196-0644(85)80636-3.

Abstract

Auscultation or palpation of blood pressure in critically ill patients by emergency medical technicians (EMTs) can be difficult, if not impossible, because of ambient noise, motion artifact, limited access to patients, or weak pulses. Automated blood pressure monitors (ABPMs) have been designed to overcome these problems during field emergencies and patient transport. Our study compared blood pressure measurements taken by EMTs with measurements provided by a Lifestat ABPM. Measurements in emergency patients on scene, during transport, in the emergency department (ED), and in a controlled environment were compared. Measurements in the various sites were obtained from 57 patients, and provision was made for two measurements at each site. Comparison of on-scene systolic blood pressures yielded a mean absolute systolic difference of 10.46 +/- 1.42 mm Hg and a mean absolute diastolic difference of 9.33 +/- 1.32 mm Hg. During transport systolic pressures showed a mean absolute difference of 11.50 +/- 1.72 mm Hg, and diastolic pressures showed a mean absolute difference of 7.59 +/- 1.16 mm Hg. Mean absolute differences in the ED were 11.23 +/- 1.49 mm Hg systolic and 8.37 +/- 1.25 mm Hg diastolic. Ninety comparison measurements in a controlled environment yielded a mean absolute systolic difference of 8.74 +/- 0.87 mm Hg and a mean absolute diastolic difference of 7.97 +/- 0.72 mm Hg. Comparison of mean diastolic pressure differences between EMT and ABPM measurements in various settings revealed some small, but statistically significant, discrepancies that were not considered clinically relevant.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

由于环境噪音、运动伪影、接近患者受限或脉搏微弱,急诊医疗技术人员(EMT)对重症患者进行血压听诊或触诊即便并非不可能,也会很困难。自动血压监测仪(ABPM)旨在克服现场急救和患者转运过程中的这些问题。我们的研究比较了EMT测量的血压与Lifestat ABPM提供的测量值。对急诊患者在现场、转运途中、急诊科(ED)以及在可控环境下的血压测量值进行了比较。从57名患者身上获取了各个部位的测量值,且每个部位进行了两次测量。现场收缩压比较得出平均绝对收缩压差值为10.46±1.42毫米汞柱,平均绝对舒张压差值为9.33±1.32毫米汞柱。转运过程中收缩压平均绝对差值为11.50±1.72毫米汞柱,舒张压平均绝对差值为7.59±1.16毫米汞柱。在ED中,收缩压平均绝对差值为11.23±1.49毫米汞柱,舒张压平均绝对差值为8.37±1.25毫米汞柱。在可控环境下进行的90次比较测量得出平均绝对收缩压差值为8.74±0.87毫米汞柱,平均绝对舒张压差值为7.97±0.72毫米汞柱。对不同场景下EMT和ABPM测量的平均舒张压差值进行比较,发现了一些虽小但具有统计学意义的差异,不过这些差异不被认为具有临床相关性。(摘要截选至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验