Suppr超能文献

通过五次坐立试验进行功能能力评估:高海拔地区居民的参考值

Functional capacity assessment through five-repetition sit-to-stand test: Reference values for people living at high-altitude.

作者信息

Dávila-Oña Sofía, Morales-Satan Mauricio, Torres Castro Rodrigo, Hidrovo-Moreno Cristhel, Otto-Yáñez Matías, Caicedo-Trujillo Saul, Gualotuña-Vasco Clara, Vera-Uribe Roberto, Bonilla-Yacelga Klever, Solis-Navarro Lilian

机构信息

Facultad de Enfermería, Pontificia Universidad Católica Del Ecuador, Quito, Ecuador.

Hospital General Docente de Calderon, Universidad Tecnológica Equinoccial (UTE), Quito, Ecuador.

出版信息

Medwave. 2025 May 14;25(4):e3059. doi: 10.5867/medwave.2025.04.3059.

Abstract

INTRODUCTION

The five repetitions sit-to-stand test is commonly used to evaluate physical function, mainly to determine the risk of falls, and is also included as a component in other evaluations, such as the Short Physical Performance Battery. However, reference values are currently unavailable for populations living at high altitudes. This study aimed to establish normative values for the five repetitions sit-to-stand test in the population living 2500 meters above sea level.

METHODS

A multicenter, cross-sectional research was carried out, collecting data from two high-altitude cities in Ecuador. Healthy adults aged 18 to 80 were recruited. Anthropometric measurements, physical activity levels, and tobacco use were registered. Reference equations were determined using multiple linear regression separately for men and women. The predictive model was generated using stepwise method.

RESULTS

400 healthy subjects (58% women) were recruited in the study. The participants had a median (P25 to P75) height of 1.62 (1.56 to 1.68) m, weight of 63.0 (57.8 to 70.1) kg, and Body Mass Index of 24.2 (22.5 to 26.0) kg/m. For men aged 18 to 29 years, the results for the five repetitions sit-to-stand test ranged from (P25 to P75) 5.1 to 9.3 seconds and between 8.2 to 12.2 seconds for people aged 70 to 80 years. For women aged 18 to 29 years, the results for five repetitions sit-to-stand test ranged from (P25 to P75) 5.0 to 7.9 seconds and between 8.2 to 14.3 seconds in the range 70 to 80 years.

CONCLUSIONS

Reference values were established for the five repetitions sit-to-stand test in the healthy population living at high altitudes, between 18 and 80 years old.

摘要

引言

五次坐立试验常用于评估身体功能,主要用于确定跌倒风险,也是其他评估(如简短体能状况量表)的组成部分。然而,目前尚无生活在高海拔地区人群的参考值。本研究旨在建立海拔2500米以上人群五次坐立试验的规范值。

方法

进行了一项多中心横断面研究,收集了厄瓜多尔两个高海拔城市的数据。招募了18至80岁的健康成年人。记录了人体测量数据、身体活动水平和烟草使用情况。分别使用多元线性回归为男性和女性确定参考方程。采用逐步法生成预测模型。

结果

本研究招募了400名健康受试者(58%为女性)。参与者的身高中位数(第25至第75百分位数)为1.62(1.56至1.68)米,体重为63.0(57.8至70.1)千克,体重指数为24.2(22.5至26.0)千克/平方米。18至29岁男性的五次坐立试验结果范围(第25至第75百分位数)为5.1至9.3秒,70至80岁人群为8.2至12.2秒。18至29岁女性的五次坐立试验结果范围(第25至第75百分位数)为5.0至7.9秒,70至80岁范围为8.2至14.3秒。

结论

建立了18至80岁生活在高海拔地区健康人群五次坐立试验的参考值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验