Suppr超能文献

用于头颈部超声认证的多项选择题测试的开发与验证

Development and validation of a multiple-choice test for head and neck ultrasound certification.

作者信息

Mikkelsen August Krogh, Kuenzel Julian, Orloff Lisa A, Sebelik Merry E, McQueen Andrew, Madani Gitta, Konge Lars, Yang Tsung-Lin, Melchiors Jacob, Weimer Johannes, Todsen Tobias

机构信息

Department of Otorhinolaryngology, Head and Neck Surgery and Audiology, Copenhagen University Hospital - Rigshospitalet, Inge Lehmanns vej 8, Copenhagen, 2100, Denmark.

Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

出版信息

Eur Arch Otorhinolaryngol. 2025 Jul 12. doi: 10.1007/s00405-025-09533-3.

Abstract

PURPOSE

This prospective trial aimed to develop and gather validity evidence for a theoretical test in head and neck ultrasound (HNUS).

METHODS

Seven HNUS experts from Europe, North America, and Asia participated in a Delphi study to reach consensus on multiple choice test (MCT) items. Novices (n=56) and experienced HNUS operators (n=22) were then invited to take the full MCT. Based on their answers, an item-response analysis selected the MCT items with the best performance. Generalizability theory determined the number of MCT items sufficient for certification. An ANOVA test examined the MCT's ability to distinguish novices from experts and contrasting groups' standard setting was used to establish a cut-off test score. A group of physicians (n=23) was tested at a formal ultrasound course, and pass-fail consequences for the final test were evaluated.

RESULTS

Over three Delphi rounds, 64 items were revised and 21 were excluded, yielding 106 items. The item-response analysis found nine items with low discrimination that were excluded based on the MCQ answers from 78 novices and experienced physicians who had taken the test. The final 97 test items had a high internal consistency reliability of 0.97, and an MCT with 15 items was found sufficient for certification purposes. The MCT could significantly discriminate between novices (mean 51.1, SD 13.8) and experienced participants (mean 92.0, SD 3.1), p < 0.001. A pass-fail score of 83 was established. At a formal introduction ultrasound course, 57% of the participants passed the MCT at the established pass-fail score.

CONCLUSION

The developed MCT for HNUS, based on international expert consensus, has multiple sources of validity evidence to support its use as part of a thorough certification process.

摘要

目的

这项前瞻性试验旨在开发并收集头颈部超声(HNUS)理论测试的效度证据。

方法

来自欧洲、北美和亚洲的7位HNUS专家参与了一项德尔菲研究,以就多项选择题(MCT)项目达成共识。随后邀请新手(n = 56)和经验丰富的HNUS操作人员(n = 22)参加完整的MCT。根据他们的答案,进行项目反应分析以选择表现最佳的MCT项目。概化理论确定了足以用于认证的MCT项目数量。方差分析测试检验了MCT区分新手和专家的能力,并使用对比组标准设定来确定及格分数。一组医生(n = 23)在正式的超声课程中接受测试,并评估最终测试的及格/不及格结果。

结果

经过三轮德尔菲研究,修订了64个项目,排除了21个项目,得到106个项目。项目反应分析发现9个辨别力低的项目,根据78名参加过测试的新手和经验丰富的医生的多项选择题答案将其排除。最终的97个测试项目具有0.97的高内部一致性信度,发现15个项目的MCT足以用于认证目的。MCT能够显著区分新手(平均51.1,标准差13.8)和经验丰富的参与者(平均92.0,标准差3.1),p < 0.001。确定及格分数为83分。在正式的超声入门课程中,57%的参与者以既定的及格/不及格分数通过了MCT。

结论

基于国际专家共识开发的HNUS的MCT有多种效度证据来源,以支持其作为全面认证过程一部分的使用。