Suppr超能文献

腹腔穿刺术并发症发生率与超声的应用:退伍军人事务医疗系统中即时超声培训课程的影响

Paracentesis complication rates and use of ultrasound: impact of a point-of-care ultrasound training course in the veterans affairs healthcare system.

作者信息

Nathanson Robert, Khosla Rahul, Theophanous Rebecca, Basrai Zahir, Agunbiade Abdulkareem A, Schott Christopher, Boyd Jeremy, Mader Michael J, Murray Kevin J, Pugh Jacqueline A, Finley Erin P, Soni Nilam J

机构信息

South Texas Veterans Health Care System, Medicine Service, San Antonio, Texas, United States.

Division of Hospital Medicine, Department of Medicine, University of Texas Health San Antonio, 7703 Floyd Curl Dr, MC 7982, San Antonio, 78229, Texas, United States.

出版信息

BMC Med Educ. 2025 Aug 12;25(1):1161. doi: 10.1186/s12909-025-07656-z.

Abstract

BACKGROUND

Point-of-care ultrasound (POCUS) training courses have been shown to increase knowledge and skills among physicians, but few studies have examined their impact on clinical outcomes. We assessed the frequency of ultrasound usage and complication rates of paracentesis after implementing a POCUS training course in the Veterans Affairs (VA) health care system.

METHODS

A retrospective observational study was conducted of VA medical centers that participated in a POCUS training course ("trained facilities") versus matched control facilities. Rates of paracentesis performed in non-radiology settings with and without ultrasound guidance and procedural complications were collected from the VA corporate data warehouse (CPT and ICD-10 procedure and diagnosis codes) and pre- and post-course surveys of course participants. A best fit linear regression line was established for quarterly rates of each group and the y-intercept and slope of each line was compared.

RESULTS

Data were compared from 16 trained versus 32 matched control facilities where 10,375 and 22,103 paracenteses were performed, respectively, from October 2015 to March 2025. At baseline, ultrasound guidance was used less frequently in trained versus matched control facilities (39% vs. 78.3%, p < 0.0001). However, trained facilities demonstrated a greater quarterly increase in ultrasound use (1.20% vs. -0.14% per quarter, p < 0.0001). By the end of the study, trained facilities surpassed control facilities in use of ultrasound guidance (84.6% vs. 73.0%, p < 0.001). The overall complication rate was low (2.4 per 1,000 procedures) and there was no significant difference in trends between trained and matched control facilities.

CONCLUSIONS

Participation in a national POCUS training course was associated with increased use of ultrasound guidance for paracentesis but not with statistically significant changes in complication rates. Further study is warranted to explore effect of POCUS training on procedural outcomes of paracentesis.

摘要

背景

床旁超声(POCUS)培训课程已被证明可增加医生的知识和技能,但很少有研究考察其对临床结局的影响。我们评估了在退伍军人事务部(VA)医疗保健系统中实施POCUS培训课程后超声的使用频率和腹腔穿刺术的并发症发生率。

方法

对参加POCUS培训课程的VA医疗中心(“培训设施”)与匹配的对照设施进行了一项回顾性观察研究。从VA企业数据仓库(CPT和ICD - 10程序及诊断代码)以及课程参与者的课前和课后调查中收集在有无超声引导下非放射科环境中进行腹腔穿刺术的比率和手术并发症。为每组的季度比率建立最佳拟合线性回归线,并比较每条线的y轴截距和斜率。

结果

比较了16个培训设施与32个匹配对照设施的数据,2015年10月至2025年3月期间分别进行了10375次和22103次腹腔穿刺术。在基线时,培训设施与匹配对照设施相比,超声引导的使用频率较低(39%对78.3%,p < 0.0001)。然而,培训设施的超声使用季度增加幅度更大(每季度1.20%对 - 0.14%,p < 0.0001)。到研究结束时,培训设施在超声引导的使用方面超过了对照设施(84.6%对73.0%,p < 0.001)。总体并发症发生率较低(每1000例手术2.4例),培训设施与匹配对照设施之间的趋势没有显著差异。

结论

参加全国性POCUS培训课程与腹腔穿刺术超声引导使用的增加相关,但与并发症发生率的统计学显著变化无关。有必要进一步研究以探讨POCUS培训对腹腔穿刺术手术结局的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aef8/12341121/56fb1778ca9e/12909_2025_7656_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验