Suppr超能文献

通过琼脂糖凝胶电泳对血清脂蛋白进行定量分析:与分析超速离心法比较以脂蛋白浓度单位(毫克/100毫升)进行标准化。

Quantitation of serum lipoproteins by electrophoresis on agarose gel: standardization in lipoprotein concentration units (mg-100 ml) by comparison with analytical ultracentrifugation.

作者信息

Hulley S B, Cook S G, Wilson W S, Nichaman M Z, Hatch F T, Lindgren F T

出版信息

J Lipid Res. 1971 Jul;12(4):420-33.

PMID:4132070
Abstract

Lipoprotein electrophoresis on agarose gel has been modified to allow estimation of the absolute quantity of each fraction. The reproducibility of the method is illustrated by 12 determinations in a single day on serum from one normal subject: mean total dye uptake was 302 +/- 9 (sd "corrected dye units," and the percentages of beta-, pre-beta, and alpha-lipoprotein were 56.1 +/- 0.9, 29.1 +/- 0.4, and 14.8 +/- 0.7, respectively. Reproducibility over a period of 8 months was also demonstrated. Serum lipoproteins of five normal and 15 hyperlipidemic individuals determined by this technique were compared with values obtained by analytical ultracentrifugation. The correlation coefficients were: 0.993 for pre-beta-LP vs. VLDL, 0.978 for beta-LP vs. LDL, and 0.867 for alpha-LP vs. HDL. Lipoprotein values obtained by paper electrophoresis were also correlated with those of the analytical ultracentrifuge, but to a lesser degree (r = 0.956, 0.691, and 0.786, respectively). Values for LDL and VLDL which were measured by refractometry after preparative ultracentrifugation were very similar to those obtained from the analytical ultracentrifuge. Serum triglyceride concentration was highly correlated (r = 0.972) with the agarose values for pre-beta-LP; serum cholesterol concentration was correlated (r = 0.673) with beta-LP. It is proposed that the standard curves of the comparisons with the analytical ultracentrifugal values be used to convert the corrected dye units of electrophoresis on agarose gel to mg/100 ml of specific lipoprotein.

摘要

琼脂糖凝胶上的脂蛋白电泳已被改进,以允许估计各组分的绝对量。该方法的重现性通过对一名正常受试者的血清在一天内进行12次测定来说明:平均总染料摄取量为302±9(标准差,“校正染料单位”),β-脂蛋白、前β-脂蛋白和α-脂蛋白的百分比分别为56.1±0.9、29.1±0.4和14.8±0.7。还证明了8个月期间的重现性。用该技术测定的5名正常人和15名高脂血症患者的血清脂蛋白与通过分析超速离心获得的值进行了比较。相关系数分别为:前β-脂蛋白与极低密度脂蛋白(VLDL)为0.993,β-脂蛋白与低密度脂蛋白(LDL)为0.978,α-脂蛋白与高密度脂蛋白(HDL)为0.867。纸电泳获得的脂蛋白值也与分析超速离心机的值相关,但程度较小(r分别为0.956、0.691和0.786)。制备性超速离心后通过折射法测量的LDL和VLDL值与分析超速离心机获得的值非常相似。血清甘油三酯浓度与前β-脂蛋白的琼脂糖值高度相关(r = 0.972);血清胆固醇浓度与β-脂蛋白相关(r = 0.673)。建议使用与分析超速离心值比较的标准曲线,将琼脂糖凝胶电泳的校正染料单位转换为每100 ml特定脂蛋白的mg数。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验