Suppr超能文献

Doxycycline determination in human serum and urine by high-performance liquid chromatography.

作者信息

De Leenheer A P, Nelis H J

出版信息

J Pharm Sci. 1979 Aug;68(8):999-1002. doi: 10.1002/jps.2600680821.

Abstract

A reversed-phase high-performance liquid chromatographic method for quantitative doxycycline determination in human serum and urine is described. The drug was extracted from buffered (pH 6.1) serum or urine into ethyl acetate. A structural analog, demeclocycline, was added as the internal standard. A 10-cm X 2-mm i.d., 5-micrometers Lichrosorb RP8 column with acetonitrile-0.1 M citric acid as the eluent was used. The effluent was monitored at 350 nm. The extraction recovery from spiked serum was 87-8 +/- 4.3% (mean +/- SD, n = 11); for urine, a value of 92.2 +/-2.0% (mean +/- SD, n = 10) was found. Within-run and within-day relative standard deviations averaged (x = 2.5 micrograms/ml, n = 10) and 4.75% (x = 2.6 micrograms/ml, n = 9), respectively. The detection limit was estimated at 50 ng/ml of serum. No significant extra peaks were observed in chromatograms obtained on serum or urine extracts, suggesting the probable absence of metabolic processes in vivo.