Suppr超能文献

手动纯音测听法与自描(贝凯西)测听法所测听力阈值的比较。

Comparison of the hearing threshold measured by manual pure-tone and by self-recording (Békésy) audiometry.

作者信息

Erlandsson B, Håkanson H, Ivarsson A, Nilsson P

出版信息

Audiology. 1979;18(5):414-29. doi: 10.3109/00206097909070067.

Abstract

The hearing threshold of 115 subjects aged 25--63 years and working on a shipyard were determined both by Békésy sweep audiometry and by conventional manual octave pure-tone audiometry at fixed audiometric frequencies. The attenuation rate was 2.5 dB s-1 with pulsed-tone presentation and the sweep time from 0.25 to 10 kHz was 400 s for the Békésy audiometer. Manual pure-tone audiometry was performed in 5-dB steps. The Békésy method gave the lowest values for the hearing thresholds. It has been possible to find a useful linear relation between pure-tone and Békésy hearing thresholds. With the help of a retest experiment, it has been established, that the standard deviations of hearing thresholds obtained under similar conditions in a pure-tone investigation are about twice as large as those obtained in a Békésy investigation.

摘要

对115名年龄在25至63岁之间、在造船厂工作的受试者,分别采用贝凯西连续扫频听力测定法和传统手动倍频程纯音听力测定法在固定听力测定频率下测定其听力阈值。采用脉冲音呈现时,衰减率为2.5 dB s-1,贝凯西听力计从0.25至10 kHz的扫频时间为400秒。手动纯音听力测定以5 dB为步长进行。贝凯西方法得出的听力阈值最低。已经能够找到纯音听力阈值与贝凯西听力阈值之间有用的线性关系。通过复测实验确定,在纯音检查中,在类似条件下获得的听力阈值的标准差大约是在贝凯西检查中获得的标准差的两倍。