Mould G P, Stout G, Aherne G W, Marks V
Ann Clin Biochem. 1978 Jul;15(4):221-5. doi: 10.1177/000456327801500147.
A radioimmunoassay for the measurement of amitriptyline and nortriptyline in serum, saliva, and urine is described. The sensitivity of the assay is such that 0.5 ng/ml of drug can be measured, although the assay does not distinguish between amitriptyline and nortriptyline. Other tricyclic compounds cross-react with the antiserum to varying degrees, but the metabolites of amitriptyline did not significantly cross-react. Total tricyclic compounds were detected in serum and saliva after single oral doses of amitriptyline, although the absorption was slow.
本文描述了一种用于测量血清、唾液和尿液中阿米替林和去甲替林的放射免疫分析方法。该分析方法的灵敏度可达可测量0.5纳克/毫升的药物,不过该分析无法区分阿米替林和去甲替林。其他三环类化合物与抗血清有不同程度的交叉反应,但阿米替林的代谢产物没有明显的交叉反应。单次口服阿米替林后,在血清和唾液中检测到了总三环类化合物,尽管吸收缓慢。