Micro-organisms originating from the dialysate compartment invaded the blood compartment of ' Rhodial RP6 ' haemodialysers in 16 out of 639 dialyses investigated (2.5 per cent). Analysis of the data suggested that the probable access of bacteria to the blood compartment was by way of minor defects in the dialysis membrane. The patients experienced no obvious symptoms or signs of sepsis which could be ascribed to the presence of micro-organisms in the blood compartment.

摘要

在所调查的639次透析中,有16次(2.5%)来自透析液腔的微生物侵入了“Rhodial RP6”血液透析器的血液腔。数据分析表明,细菌进入血液腔的可能途径是通过透析膜的微小缺陷。患者没有出现可归因于血液腔中存在微生物的明显败血症症状或体征。