Suppr超能文献

基于病毒抗原合成免疫酶定量法的灵敏干扰素检测法。

Sensitive interferon assay based on immunoenzymatic quantification of viral antigen synthesis.

作者信息

Julkunen I, Linnavuori K, Hovi T

出版信息

J Virol Methods. 1982 Oct;5(2):85-91. doi: 10.1016/0166-0934(82)90085-4.

Abstract

A sensitive enzyme immunoassay (EIA) for determining the biological activity of human interferon was developed. Green monkey kidney (Vero) cells and human embryonic lung (HEL) cells were grown in microtitre plates, treated with leukocyte interferon (IFN alpha) and infected with vesicular stomatitis virus (VSV). Cells were fixed with paraformaldehyde and permeabilized with Triton X-100. Viral antigen synthesis was measured by labelling the cells with VSV antiserum followed sequentially by protein A horseradish peroxidase conjugate and o-phenylenediamine. Interferon activity was detected as a lowering of the absorbance value from that of the virus control wells, reflecting the inhibition of virus protein synthesis by interferon. The minimum amount of interferon producing statistically significant (P less than 0.01) decrease of absorbance in Vero cells was 1-5 international units (I.U.)/ml as in the standard plaque reduction test the detection limit was 7.5 I.U./ml or more. In HEL cells the detection limit was 1 I.U./ml measured by EIA. The EIA for interferon activity is at least as sensitive as the traditional plaque reduction test. It is reproducible, easy to automatise and requires 7-10 times less cell culture materials than the plaque reduction test. We find it preferential especially when large numbers of specimens with limited volumes are to be analysed for interferon activity.

摘要

开发了一种用于测定人干扰素生物活性的灵敏酶免疫测定法(EIA)。绿猴肾(Vero)细胞和人胚肺(HEL)细胞在微量滴定板中培养,用白细胞干扰素(IFNα)处理后感染水疱性口炎病毒(VSV)。细胞用多聚甲醛固定,并用Triton X-100通透处理。通过依次用VSV抗血清、蛋白A辣根过氧化物酶缀合物和邻苯二胺标记细胞来测量病毒抗原合成。干扰素活性通过与病毒对照孔的吸光度值降低来检测,反映干扰素对病毒蛋白合成的抑制作用。在Vero细胞中产生统计学上显著(P小于0.01)吸光度降低的干扰素最小量为1-5国际单位(I.U.)/ml,因为在标准蚀斑减少试验中检测限为7.5 I.U./ml或更高。在HEL细胞中,通过EIA测定的检测限为1 I.U./ml。干扰素活性的EIA至少与传统的蚀斑减少试验一样灵敏。它具有可重复性,易于自动化,并且所需的细胞培养材料比蚀斑减少试验少7-10倍。我们发现特别是当要分析大量体积有限的标本的干扰素活性时,它更具优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验