Fisher G A
Transfusion. 1983 Mar-Apr;23(2):152-4. doi: 10.1046/j.1537-2995.1983.23283172855.x.
The manual Polybrene test described by Lalezari and Jiang was tested in parallel with saline, papain, and antiglobulin tests routinely used in this laboratory for antibody detection and identification and compatibility testing. Among 5381 patient sera tested, 264 antibodies were detected in 244 patients. In all, 6353 units of blood were crossmatched. The manual Polybrene test was generally more sensitive than the other three tests and was much faster. In order to detect anti-K, a supplementary antiglobulin phase was needed. The manual Polybrene test was less useful in detecting IgM antibodies.
拉莱扎里和江所描述的手工聚凝胺试验,与本实验室常规用于抗体检测、鉴定及交叉配血试验的生理盐水试验、木瓜蛋白酶试验和抗球蛋白试验同时进行了检测。在检测的5381份患者血清中,244例患者检测到264种抗体。总共进行了6353单位血液的交叉配血。手工聚凝胺试验总体上比其他三种试验更灵敏,且速度快得多。为检测抗-K抗体,需要一个补充抗球蛋白阶段。手工聚凝胺试验在检测IgM抗体方面用处较小。