Freeman M J, Sands-Freeman L, Armstrong C H
Am J Vet Res. 1983 Sep;44(9):1734-7.
Standardized enzyme-linked immunosorbent assays for the serodiagnosis of mycoplasmal pneumonia of swine were developed, using the traditional Microtiter plate method and a method based on semiautomated processor-analyzer instrumentation. The results of the 2 procedures were not significantly different when the titers of positive and negative anti-Mycoplasma hyopneumoniae standard reference sera were determined in triplicate in 3 separate experiments. Although both methods yielded reproducible results, the instrument-assisted enzyme-linked immunosorbent assay would be preferable if large numbers of samples are to be tested.
已开发出用于猪支原体肺炎血清诊断的标准化酶联免疫吸附测定法,采用传统的微量滴定板法和基于半自动处理器分析仪仪器的方法。在3个独立实验中,对阳性和阴性猪肺炎支原体标准参考血清的效价进行一式三份测定时,这两种方法的结果没有显著差异。尽管两种方法都产生了可重复的结果,但如果要检测大量样本,仪器辅助酶联免疫吸附测定法会更可取。