Creamatocrit: simple clinical technique for estimating fat concentration and energy value of human milk.

作者信息

Lucas A, Gibbs J A, Lyster R L, Baum J D

出版信息

Br Med J. 1978 Apr 22;1(6119):1018-20. doi: 10.1136/bmj.1.6119.1018.

Abstract

A simple micromethod has been devised for estimating the fat and energy content of human milk based on the centrifugation of milk in a haematocrit centrifuge. The percentage of cream, or "creamatocrit," is read from the haematocrit capillary tube and is linearly related to the fat and energy content. The technique, which is rapid and cheap, may be used in clinical practice, in research, and in epidemiological studies.

摘要

已设计出一种简单的微量方法,用于基于在血细胞比容离心机中对母乳进行离心来估算母乳中的脂肪和能量含量。从血细胞比容毛细管中读取乳脂百分比,即“乳脂比容”,它与脂肪和能量含量呈线性关系。该技术快速且成本低廉,可用于临床实践、研究和流行病学研究。