Halton D M, Peterson W D, Hukku B
In Vitro. 1983 Jan;19(1):16-24. doi: 10.1007/BF02617989.
Procedures that involve cell cultures require careful quality control to avoid inter- and intraspecies contamination. We have developed an electrophoresis technique that can be used routinely in cell culture laboratories to monitor cell line integrity. The method involves the isoenzymatic separation of nine polymorphic enzymes, three of which can be used for cell line species determinations and seven of which can be used for human cell line characterizations. Examples of how the system has been applied to both inter- and intraspecies identifications are described. The routine application of this protocol would be a valuable asset for laboratories concerned with establishing effective cell culture quality control.
涉及细胞培养的操作需要严格的质量控制,以避免种间和种内污染。我们开发了一种电泳技术,可在细胞培养实验室中常规使用,以监测细胞系的完整性。该方法涉及九种多态性酶的同工酶分离,其中三种可用于确定细胞系的物种,七种可用于表征人类细胞系。文中描述了该系统如何应用于种间和种内鉴定的实例。对于关注建立有效细胞培养质量控制的实验室而言,该方案的常规应用将是一项宝贵的资产。