We have studied the interrelation of left ventricle and arterial system in the anesthetized open-thorax cat. The ventricle was characterized by its pump function graph, relating mean ventricular pressure (Plv) and mean aortic flow (F). The pump function graph was determined by means of an artificial periphery and on a beat-to-beat basis. The periphery was characterized by relating mean aortic pressure (Pao) and mean flow. Mean aortic and mean left ventricular pressure could be related over a wide range of values by a proportionality factor Pao = a . Plv. In a series of five separate experiments a value of a = 1.72 +/- 0.14 (mean +/- SD) was found. This simplified relation allows direct comparison of apparent source resistance (i.e., slope of pump function graph), (Rs), and peripheral resistance (Rp). It was also found experimentally that total external power (w) could be calculated from mean aortic pressure and mean flow as well as from mean left ventricular pressure and mean flow (thus from the pump function graph) by w = c . Pao . F = c . a . Plv . F. The value of c = 1.16 +/- 0.12 (mean +/- SD, n = 4). Maximum external power was predicted for Rp/Rs = Pao/Plv = a. In six different cats Rp/Rs ratio in the working point (i.e., mean left ventricular pressure and mean flow when the normal periphery loaded the heart) was found to be Rp/Rs = 2.63 +/- 0.92. This value could not be shown to differ from that in the point where maximal external power was found, i.e., Rp/Rs = 1.81 +/- 0.08 (n = 6).

摘要

我们研究了麻醉开胸猫左心室与动脉系统的相互关系。通过泵功能图来描述心室,该图关联了平均心室压力(Plv)和平均主动脉流量(F)。泵功能图通过人工外周装置逐搏测定。外周则通过关联平均主动脉压力(Pao)和平均流量来描述。在很宽的数值范围内,平均主动脉压力和平均左心室压力可通过比例因子Pao = a·Plv相关联。在一系列五个独立实验中,发现a值为1.72±0.14(均值±标准差)。这种简化关系允许直接比较表观源阻力(即泵功能图的斜率)(Rs)和外周阻力(Rp)。实验还发现,总外部功率(w)可由平均主动脉压力和平均流量以及平均左心室压力和平均流量(即通过泵功能图)计算得出,公式为w = c·Pao·F = c·a·Plv·F。c值为1.16±0.12(均值±标准差,n = 4)。预测当Rp/Rs = Pao/Plv = a时达到最大外部功率。在六只不同的猫中,发现工作点(即正常外周负荷心脏时的平均左心室压力和平均流量)的Rp/Rs比值为Rp/Rs = 2.63±0.92。该值与发现最大外部功率点处的比值(即Rp/Rs = 1.81±0.08,n = 6)无显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验