Ito K, Niwa M, Koba T
Tokai J Exp Clin Med. 1983 Jul;8(3):247-55.
A newly developed reagent strip method for determination of urinary specific gravity is described. This reagent strip (Chemical S.G., Ames Co.) contains polyelectrolyte which is sensitive to the cation in solution. The urinary specific gravity is mainly decided by cation (Na+ and K+) concentrations in urine. As a result, the reagent strip gave measurements that corresponded to those measured by refractometry and gravimetry of NaC1 solution. Urea and glucose gave increased values by the refractometer, whereas the reagent strip did not cause changes. The values of urinary specific gravity obtained from reagent strip showed not only good correlations (r = 0.79-0.93) with the refractometry and gravimetry but also urinary osmolarity. This reagent strip method proved to be a most convenient tool for routine urinalysis because of the good reproducibility and accuracy considering its easy handling.
本文描述了一种新开发的用于测定尿比重的试剂条法。这种试剂条(化学尿比重试剂条,艾姆斯公司)含有对溶液中的阳离子敏感的聚电解质。尿比重主要由尿液中的阳离子(Na +和K +)浓度决定。因此,该试剂条给出的测量值与通过折射法和重量法测量氯化钠溶液得到的值相对应。折射仪测量尿素和葡萄糖时数值会升高,而试剂条不会引起变化。从试剂条获得的尿比重值不仅与折射法和重量法有良好的相关性(r = 0.79 - 0.93),而且与尿渗透压也有良好相关性。考虑到其易于操作,这种试剂条法具有良好的重现性和准确性,被证明是常规尿液分析中最方便的工具。