Suppr超能文献

新生儿期经皮二氧化碳监测

Transcutaneous carbon dioxide monitoring in the newborn period.

作者信息

Laptook A, Oh W

出版信息

Crit Care Med. 1981 Oct;9(10):759-60. doi: 10.1097/00003246-198110000-00019.

Abstract

One hundred ninety-one simultaneous PtcCO2 and PaCO2 values were recorded from 20 neonates using a heated CO2 sensor. Gestational age and birth weight ranged from 30--44 weeks and 1.22--3.4 kg, respectively. An overestimation of PaCO2 was consistently found. Regression analysis revealed a slope of 1.29, an intercept of 18 mm Hg and a correlation coefficient of 0.85 (p less than 0.001). The PtcCO2 sensor has multiple potential uses in the sick neonate but further experience is necessary to provide adequate correction factors.

摘要

使用加热式二氧化碳传感器记录了20例新生儿的191组同时测得的经皮二氧化碳分压(PtcCO2)和动脉血二氧化碳分压(PaCO2)值。胎龄和出生体重分别为30 - 44周和1.22 - 3.4千克。持续发现PaCO2存在高估情况。回归分析显示斜率为1.29,截距为18毫米汞柱,相关系数为0.85(p < 0.001)。PtcCO2传感器在患病新生儿中有多种潜在用途,但需要更多经验来提供合适的校正因子。