通过重复呼吸技术对麻醉大鼠进行二氧化碳通气反应实验。

CO2-ventilatory response of the anesthetized rat by rebreathing technique.

作者信息

Hayashi F, Yoshida A, Fukuda Y, Honda Y

出版信息

Pflugers Arch. 1982 Mar;393(1):77-82. doi: 10.1007/BF00582395.

Abstract

The ventilatory response to CO2 in rats under sodium pentobarbital anesthesia has been measured using the rebreathing technique. The animal rebreathed through a tracheal cannula for a period of 4 min from an apparatus of 200-400 ml capacity, containing 5-6% CO2 in O2. Pco2 in the rebreathing apparatus (PappCO2), instantaneously Vt, f, and Ve were monitored before, during, and after rebreathing. During the rebreathing run, PappCO2 and Paco2 rose linearly from 35-40 to 65-70 mm Hg; there was no significant difference between PappCO2 and Paco2 at any time during rebreathing. Vt and Ve increases almost linearly with the rise of PappCO2, while f increased to a maximum within 2 min of rebreathing. In the rat, Vt regulation seemed to operate exclusively as a proportional control system in response to linearly increasing CO2 stimulus. The slopes of PappCO2, Vt or Ve response curves varied considerably during the time course of the experiment, depending upon the level of anesthesia, even though there was no large change in Ve in the control periods which were under hyperoxic conditions. However, a significant linear relationship was seen between f in the respective control period and the slope of PappCO2-Vt response at various levels of anesthesia. We concluded that the rebreathing technique can be applied in small experimental animals and that changes in the sensitivity of the respiratory control system to a CO2 stimulus by anesthesia can be easily monitored by repeating the rebreathing test.

摘要

采用重复呼吸技术测定了戊巴比妥钠麻醉下大鼠对二氧化碳的通气反应。动物通过气管插管从容量为200 - 400 ml、含5 - 6%二氧化碳的氧气装置中重复呼吸4分钟。在重复呼吸前、期间和之后,监测重复呼吸装置中的Pco2(PappCO2)、瞬时Vt、f和Ve。在重复呼吸过程中,PappCO2和Paco2从35 - 40 mmHg线性升至65 - 70 mmHg;重复呼吸期间任何时候PappCO2和Paco2之间均无显著差异。Vt和Ve几乎随PappCO2的升高呈线性增加,而f在重复呼吸2分钟内升至最大值。在大鼠中,Vt调节似乎仅作为一种比例控制系统来响应线性增加的二氧化碳刺激。在实验过程中,PappCO2、Vt或Ve反应曲线的斜率变化很大,这取决于麻醉水平,尽管在高氧条件下的对照期Ve没有大的变化。然而,在各个对照期的f与不同麻醉水平下PappCO2 - Vt反应的斜率之间存在显著的线性关系。我们得出结论,重复呼吸技术可应用于小型实验动物,并且通过重复重复呼吸试验可以很容易地监测麻醉对呼吸控制系统对二氧化碳刺激敏感性的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验