Abstract

A new automated immunoperoxidase assay for the recognition of B and T lymphocytes on the Hemalog system is proposed. Lymphoïd cells are incubated with peroxidase labeled antibodies, and after manual washing, cells are run through the flow system of the machine which automatically stains the cells for peroxidase and, according to their staining for this enzyme, separates positive from negative cells. Using this method we have been able to recognize B and T lymphocytes and to count them as accurately as by routine immunological methods. Very preliminary results, concerning a few cases of chronic lymphocytic leukemia, prolymphocytic leukemia and Waldenström's macroglobulinemia are also reported. The usefulness of this new method which allows processing of 60 samples per hour is discussed.

摘要

本文提出了一种用于在血液分析仪系统上识别B淋巴细胞和T淋巴细胞的新型自动化免疫过氧化物酶检测方法。将淋巴细胞与过氧化物酶标记的抗体孵育,手动洗涤后,细胞通过机器的流动系统,该系统会自动对细胞进行过氧化物酶染色,并根据细胞对该酶的染色情况将阳性细胞与阴性细胞分离。使用这种方法,我们能够识别B淋巴细胞和T淋巴细胞,并能像常规免疫学方法一样准确地对它们进行计数。本文还报告了关于少数慢性淋巴细胞白血病、幼淋巴细胞白血病和华氏巨球蛋白血症病例的非常初步的结果。讨论了这种每小时可处理60个样本的新方法的实用性。