Suppr超能文献

用于快速鉴定肠杆菌科细菌的MS-2系统的评估

Evaluation of the MS-2 system for rapid identification of Enterobacteriaceae.

作者信息

McCracken A W, Martin W J, McCarthy L R, Schwab D A, Cooper B H, Helgeson N G, Prowant S, Robson J

出版信息

J Clin Microbiol. 1980 Nov;12(5):684-9. doi: 10.1128/jcm.12.5.684-689.1980.

Abstract

The precision, accuracy, and other performance characteristics of the MS-2 (Abbott Laboratories, Diagnostic Division, Dallas, Tex.) system for the identification of Enterobacteriaceae were evaluated in a collaborative study involving three clinical laboratories. When identifying 150 unknown, coded organisms, the MS-2 system was 97%, 98%, and 93% accurate, respectively, in three laboratories. The system showed an overall accuracy of 94% when compared with conventional manual tube methods in identifying 1,154 clinical isolates of 26 species of Enterobacteriaceae. Discrepancies between automated and conventional methods were chiefly caused by biochemical variants, especially among Enterobacter species. The MS-2 system was rapid and simple to operate and produced printed results of bacterial identification in 5 h. The cost of disposable components compared favorably with commercial, visually read systems for identifying Enterobacteriaceae.

摘要

在一项涉及三个临床实验室的协作研究中,对用于鉴定肠杆菌科细菌的MS - 2系统(雅培实验室诊断部,得克萨斯州达拉斯)的精密度、准确度及其他性能特征进行了评估。在鉴定150株未知编码菌株时,MS - 2系统在三个实验室中的准确率分别为97%、98%和93%。在鉴定26种肠杆菌科细菌的1154株临床分离株时,与传统手动试管法相比,该系统的总体准确率为94%。自动化方法与传统方法之间的差异主要由生化变异体引起,尤其是在肠杆菌属细菌中。MS - 2系统操作快速简便,5小时内即可生成细菌鉴定的打印结果。与用于鉴定肠杆菌科细菌的商业目视读取系统相比,一次性组件的成本更具优势。

相似文献

1
Evaluation of the MS-2 system for rapid identification of Enterobacteriaceae.
J Clin Microbiol. 1980 Nov;12(5):684-9. doi: 10.1128/jcm.12.5.684-689.1980.
2
Rapid and automated identification of Enterobacteriaceae with the abbott MS-2 system and API-20E versus conventional methods.
Zentralbl Bakteriol Mikrobiol Hyg A Med Mikrobiol Infekt Parasitol. 1982 May;252(1):26-34.
4
Evaluation of an automated, computerized system (automicrobic system) for Enterobacteriaceae identification.
J Clin Microbiol. 1981 Feb;13(2):331-4. doi: 10.1128/jcm.13.2.331-334.1981.
5
Clinical laboratory evaluation of the automicrobic system Enterobacteriaceae biochemical card.
J Clin Microbiol. 1981 Oct;14(4):370-5. doi: 10.1128/jcm.14.4.370-375.1981.
7
Evaluation of the Sensititre system for identification of Enterobacteriaceae.
J Clin Microbiol. 1983 Apr;17(4):647-54. doi: 10.1128/jcm.17.4.647-654.1983.
8
Clinical laboratory evaluation of the Auto-Microbic system for rapid identification of Enterobacteriaceae.
J Clin Microbiol. 1981 Mar;13(3):491-7. doi: 10.1128/jcm.13.3.491-497.1981.
9
Evaluation of the Repliscan system for identification of Enterobacteriaceae.
J Clin Microbiol. 1978 Dec;8(6):695-9. doi: 10.1128/jcm.8.6.695-699.1978.
10
Evaluation of the redesigned enterotube--a system for the identification of Enterobacteriaceae.
Appl Microbiol. 1973 Feb;25(2):301-4. doi: 10.1128/am.25.2.301-304.1973.

引用本文的文献

1
MS2 virus-like particles as a versatile platform for multi-disease vaccines: a review.
Front Immunol. 2025 Sep 3;16:1651594. doi: 10.3389/fimmu.2025.1651594. eCollection 2025.
2
Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system.
Appl Environ Microbiol. 1981 Jun;41(6):1316-20. doi: 10.1128/aem.41.6.1316-1320.1981.
3
Comparison of four rapid methods for identification of Enterobacteriaceae from blood cultures.
J Clin Microbiol. 1983 Mar;17(3):493-9. doi: 10.1128/jcm.17.3.493-499.1983.
8
Evaluation of the Quantum II and Rapid E identification systems.
J Clin Microbiol. 1984 Sep;20(3):509-14. doi: 10.1128/jcm.20.3.509-514.1984.
9
Spectral analysis of biochemical reactions used for identification of bacteria.
Eur J Clin Microbiol. 1984 Aug;3(4):310-5. doi: 10.1007/BF01977479.
10
Collaborative evaluation of the Abbott yeast identification system.
J Clin Microbiol. 1984 Jun;19(6):853-6. doi: 10.1128/jcm.19.6.853-856.1984.

本文引用的文献

2
API system: a multitube micromethod for identification of Enterobacteriaceae.
Appl Microbiol. 1972 Sep;24(3):449-52. doi: 10.1128/am.24.3.449-452.1972.
3
Evaluation of the modified Micro-ID system for identification of Enterobacteriaceae.
J Clin Microbiol. 1979 Oct;10(4):454-8. doi: 10.1128/jcm.10.4.454-458.1979.
4
Comparison of micro-ID, API 20E, and conventional media systems in identification of Enterobacteriaceae.
J Clin Microbiol. 1978 Jun;7(6):507-13. doi: 10.1128/jcm.7.6.507-513.1978.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验