Respiratory tract ciliary beat frequency (CBF) was studied to investigate the relation between nasal and tracheal CBF and the possible existence of a gradient of ciliary activity in the human tracheobronchial tree. Ciliary beat frequency was measured photometrically in nasal, tracheal, and lower lobe bronchial brushings obtained at bronchoscopy in 25 patients and in nasal, tracheal, and subsegmental airway brushings in a further 12 patients. Mean (+/- 1 SD) beat frequencies for nasal, tracheal, lower lobe bronchial, and subsegmental samples were 14.0 +/- 1.5, 14.2 +/- 1.3, 14.3 +/- 1.5, and 10.3 +/- 1.0 beats/s, respectively. Nasal, tracheal, and lower lobe bronchial beat frequencies were not significantly different (p greater than 0.05), but subsegmental airway CBF was slower than each of the others (p less than 0.001); there was a positive correlation between nasal and tracheal CBF (r = 0.71). We conclude that CBF is slower in human peripheral airways, but that nasal and tracheal rates are similar.
为了研究鼻腔和气管的纤毛摆动频率(CBF)之间的关系以及人类气管支气管树中纤毛活动梯度的可能存在情况,对呼吸道纤毛摆动频率进行了研究。对25例患者在支气管镜检查时获取的鼻腔、气管和下叶支气管刷检样本,以及另外12例患者的鼻腔、气管和亚段气道刷检样本进行了光度法测量纤毛摆动频率。鼻腔、气管、下叶支气管和亚段样本的平均(±1标准差)摆动频率分别为14.0±1.5、14.2±1.3、14.3±1.5和10.3±1.0次/秒。鼻腔、气管和下叶支气管的摆动频率无显著差异(p>0.05),但亚段气道的CBF比其他部位慢(p<0.001);鼻腔和气管的CBF之间存在正相关(r = 0.71)。我们得出结论,人类外周气道的CBF较慢,但鼻腔和气管的速率相似。